SmartPro 120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, USB, DB9, 8 Outlets

Sale!

$849.36

SmartPro 120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, USB, DB9, 8 Outlets

Add to Wishlist
Add to Wishlist
Compare
SKU: SMC1500T Category:

Description

Specifications

OVERVIEW
UPC Code 037332124555
UPS Type Line-Interactive
INPUT
Rated input current (Maximum Load) 4.1A (220V),3.9A (230V), 3.8 (240V)
Nominal Input Voltage(s) Supported 220V AC; 230V AC; 240V AC
UPS Input Connection Type C14 inlet
UPS Input Connection Description IEC320-C14 input connection accepts a variety of detachable cordsets to match country or site-specific wall receptacles
Input Phase Single-Phase
OUTPUT
Output Volt Amp Capacity (VA) 1500
Output Capacity (kVA) 1.5
Output Watt Capacity (Watts) 900
Nominal Voltage Details 230V default (voltage selection via back panel switches)
Frequency Compatibility 50 / 60 Hz
Frequency Compatibility Details Automatic frequency selection
Output Voltage Regulation (Line Mode) -9% / + 5%
Output Voltage Regulation (Battery Mode) +/- 5%
Included Output Power Cables Includes 2 C13 to C14 output power cables
Output AC Waveform (AC Mode) Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Nominal Output Voltage(s) Supported 220V; 230V; 240V
Output Receptacles (8) C13
Individually Controllable Load Banks No
BATTERY
Battery Type Valve Regulated Lead Acid (VRLA)
Full Load Runtime (min.) 8 min. (900w)
Half Load Runtime (min.) 20 min. (450w)
Expandable Runtime No
DC System Voltage (VDC) 36
Battery Recharge Rate (Included Batteries) Less than 8 hours from 10% to 90% (typical, full load discharge)
Battery Access Battery access door
Internal UPS Replacement Battery Cartridge  RBC36-SLT
Battery Replacement Description Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 182 to 278 (230v), 190 to 290 (240v), 174 to 266 (220v)
Overvoltage Correction Voltage reduction of 12% applies when input is 244 to 278 (230v), 254 to 290 (240v), 232 to 266 (220v); Voltage setpoints ±5% tolerance
Undervoltage Correction Voltage boost of 14% applies when input is 182 to 206 (230v), 190 to 216 (240v), 174 to 198 (220); Voltage setpoints ±5% tolerance
USER INTERFACE, ALERTS & CONTROLS
Switches 2 Switches control off/on power status and alarm-cancel/self-test operation; rear panel protected switches support nominal voltage selection
Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch
Audible Alarm Audible alarm indicates power failure and overload conditions
LED Indicators 9 LEDs indicate line power, battery power, AVR, overload and replace battery status – with a 3-LED level meter for load and battery charge level
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 350
UPS AC Suppression Response Time Instantaneous
UPS Dataline Suppression 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet
EMI / RFI AC Noise Suppression Yes
PHYSICAL
Primary Form Factor Tower
Cooling Method Fan
Installation Form Factors Supported with Included Accessories Tower
Primary UPS Depth (mm) 335
Primary UPS Height (mm) 259
Primary UPS Width (mm) 173
Shipping Dimensions (hwd / cm) 46.99 x 25.40 x 34.29
Shipping Weight (kg) 21.45
UPS Housing Material Steel
UPS Power Module Dimensions (hwd, cm) 25.91 x 17.27 x 33.53
UPS Power Module Weight (kg) 20.41
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load) 145
Battery Mode BTU / Hr. (Full Load) 585
AC Mode Efficiency Rating (100% Load) 94%
Audible Noise Audible Noise < 50 dBA at Front Side 1 Meter
COMMUNICATIONS
Network Management Cards SNMPWEBCARD;  WEBCARDLX ;  RELAYIOCARD
Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions
PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://www.tripplite.com/poweralert
Communications Cable USB and DB9 cabling included
WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
Network Management Card Description Network management card optional
Communications Interface DB9 Serial; Slot for SNMP/Web interface; USB
LINE / BATTERY TRANSFER
Transfer Time 4-8 milliseconds
Low Voltage Transfer to Battery Power (Setpoint) 174V (220V), 182V (230V) or 190V (240V); Voltage setpoints ±5% tolerance
High Voltage Transfer to Battery Power (Setpoint) 266V (220V), 278V (230V) or 290V (240V); Voltage setpoints ±5% tolerance
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features Auto Probe Monitoring (requires WEBCARDLX); Automatic Voltage Regulation (AVR); Hot swappable batteries; Remote management; Sine wave output; Surge/noise protection
STANDARDS & COMPLIANCE
Product Certifications GOST (Russia)
Product Compliance RoHS; SASO (Saudi Arabia); CE (Europe); FCC Part 15 Class A (USA)
WARRANTY
Product Warranty Period (International) 2-year limited warranty

Additional information

Weight 19.91 kg
Dimensions 35.56 × 24.38 × 46.48 cm
Brand