Sale!
Compare
KShs11,283,560.21
3-Phase 208V 80kVA UPS + 100kVA Input/Output Isolation Transformer Kit – 480V to 208V/208V to 480V, External Batteries Required
Description
Product Description | Tripp Lite 3-Phase 208V 80kVA UPS + 100kVA Input/Output Isolation Transformer Kit – 480V to 208V/208V to 480V, External Batteries Required – UPS – 80 kW – 80000 VA – with S3MT-100KWR480V 3-Phase100kVA Input/Output IsolationTransformers |
Device Type | UPS – active Power Factor Correction (PFC) – external |
Input Wiring | 3-phase WYE (star) |
Input Voltage | AC 120/127/208/220 V |
Output Voltage | AC 120/127/208/220 V ± 1% |
Power Capacity | 80 kW / 80000 VA |
Input Connectors | Hardwire |
Output connectors | Hardwire |
Networking | RS-232, USB, serial |
Remote Management Protocol | SNMP |
Environmental Standards | ENERGY STAR |
Manufacturer Warranty | 2-year warranty |
Bundled with | S3MT-100KWR480V 3-Phase100kVA Input/Output IsolationTransformers |
General
Device Type | UPS – active Power Factor Correction (PFC) – external |
Bundled with | S3MT-100KWR480V 3-Phase100kVA Input/Output IsolationTransformers |
Power Device
UPS Technology | On-line |
Input Voltage | AC 120/127/208/220 V |
Frequency Provided | 50/60 Hz |
Input Wiring | 3-phase WYE (star) |
Input Connectors | Hardwire |
Power Output Connectors Details | Hardwire |
Output Voltage | AC 120/127/208/220 V ± 1% – 50/60 Hz |
Power Capacity | 80 kW / 80000 VA |
Output Waveform | Sinewave |
Circuit Protection | Circuit breaker |
Efficiency | 98% Eco mode, 94% online mode |
Power Factor (PF) | 0.99 |
Total Harmonic Distortion (THD) | 3 % |
Networking
Remote Management Interface | RS-232, USB, serial |
Remote Management Protocol | SNMP |
Expansion / Connectivity
Interfaces | 1 x EPO (emergency power off) 1 x management (RS-232) – 9 pin D-Sub (DB-9) 1 x USB – 4 pin USB Type B |
Miscellaneous
Cables Included | RS-232 cable 5 ft Parallel cable 5 ft USB cable 5 ft |
Features | Integrated electrical grounding, built-in 5″ touch screen display, audible alarm, LCD display, LED indicators, cold-start function, cooling fan, double conversion, overvoltage correction, undervoltage correction |
Compliant Standards | CSA, UL 1778, FCC CFR47 Part 15 A, RETIE |
Environmental Standards
ENERGY STAR | Yes |
Manufacturer Warranty
Service & Support | Limited warranty – 2 years |
Environmental Parameters
Min Operating Temperature | 32 °F |
Max Operating Temperature | 104 °F |
Humidity Range Operating | 95% (non-condensing) |
Sound Emission | 73.9 dBA |
Additional information
Brand |
---|