SmartOnline 120V 3kVA 2.7kW On-Line Double-Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Option, ENERGY STAR

Sale!

$3,269.83

SmartOnline 120V 3kVA 2.7kW On-Line Double-Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Option, ENERGY STAR

Add to Wishlist
Add to Wishlist
Compare
SKU: SU3000RTXL2U Category:

Description

Specifications

OVERVIEW
UPC Code 037332197023
UPS Type On-Line
INPUT
Rated input current (Maximum Load) 24A maximum
Nominal Input Voltage(s) Supported 120V AC
UPS Input Connection Type L5-30P
Recommended Electrical Service 30A 120V
Input Phase Single-Phase
Input Cord Length (ft.) 10
OUTPUT
Output Volt Amp Capacity (VA) 3000
Output Capacity (kVA) 3.00
Output Watt Capacity (Watts) 2700
Output kW Capacity (kW) 2.70
Output Capacity Details INVERTER SHORT-CIRCUIT PROTECTION: Inverter short-circuit protection is electrically protected; OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% for 30 seconds, 150% for 10 seconds and >150% for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits of 120V ±10%) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits of 120V ±10%).
Power Factor 0.9
Crest Factor 3:1
Nominal Voltage Details 120V default
Frequency Compatibility 50 / 60 Hz
Frequency Compatibility Details Accepts 40 to 70Hz input frequency. Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start. Frequency conversion from 60 to 50 Hz -or- 50 to 60 Hz supported. Output capacity de-rates to 70% of normal levels during frequency conversion operation.
Output Voltage Regulation (Line Mode) +/- 2%
Output Voltage Regulation (Battery Mode) +/- 2%
Load Management Receptacles Two switchable three-outlet load banks
Output Circuit Breakers 20A (x2) – each breaker protects 3 5-15/20R outlets, L5-30R outlet is un-breakered
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Nominal Output Voltage(s) Supported 100V; 110V; 115V; 120V; 127V
Output Receptacles (6) 5-15/20R; (1) L5-30R
Individually Controllable Load Banks Yes
BATTERY
Battery Type Valve Regulated Lead Acid (VRLA)
Full Load Runtime (min.) 4.8 min. (2700w)
Half Load Runtime (min.) 13.8 min. (1350w)
Expandable Battery Runtime Supports extended runtime with optional external battery packs
Expandable Runtime Yes
External Battery Pack Compatibility  BP72V15-2U  (limit 1);  BP72V28RT-3U  (multi-pack compatible);  BP72V18-2US  (multi-pack compatible)
DC System Voltage (VDC) 72
Battery Recharge Rate (Included Batteries) Less than 8.1 hours from 10% to 90% (typical, full load discharge)
Battery Access Front panel battery access door
Internal UPS Replacement Battery Cartridge See RBC selector guide (replacement battery part number is also labeled on the internal battery door)
Battery Replacement Description Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage Regulation Description Online, double-conversion power conditioning
Overvoltage Correction ONLINE MODE: 2% output voltage regulation during overvoltages to 150
Undervoltage Correction 2% output voltage regulation during undervoltages to 80V (66-100% load)
Severe Undervoltage Correction 2% output voltage regulation during undervoltages to 70V (33-66% load) or 60V (under 33% load)
USER INTERFACE, ALERTS & CONTROLS
Switches 2 Switches control off/on power status and alarm-cancel/self-test operation
Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch
Audible Alarm Audible alarm indicates power failure, low battery, overload, replace battery and EPO operation
LED Indicators 14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 504
EMI / RFI AC Noise Suppression Yes
AC Suppression Response Time Instantaneous
PHYSICAL
Primary Form Factor Rackmount
Rack Height 2U
Cooling Method Fan
Included Mounting Accessory Description Includes 4 post rackmount installation accessories
Installation Form Factors Supported with Included Accessories 4 post 19 inch rackmount
Installation Form Factors Supported with Optional Accessories 2 post rackmount ( 2POSTRMKITWM ); Tower ( 2-9USTAND )
Minimum Required Rack Depth with External Battery Pack (cm) 77
Minimum Required Rack Depth with External Battery Pack (in.) 30.25
Minimum Required Rack Depth without External Battery Pack (cm) 74
Minimum Required Rack Depth without External Battery Pack (in.) 29.25
Primary UPS Depth (mm) 616
Primary UPS Height (mm) 88
Primary UPS Width (mm) 438
Shipping Dimensions (hwd / in.) 9.45 x 23.62 x 29.92
Shipping Weight (lbs.) 87.00
UPS Housing Material Steel
UPS Power Module Dimensions (hwd, in.) 3.46 x 17.24 x 24.25
UPS Power Module Weight (kg) 31.17
UPS Power Module Weight (lbs.) 68.72
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
Relative Humidity 5 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load) 531
AC Economy Mode BTU / Hr. (Full Load) 484.5
Battery Mode BTU / Hr. (Full Load) 1037
AC Economy Mode Efficiency Rating (100% Load) 95%
Audible Noise 50 dBA max, front-side @ 1m
COMMUNICATIONS
Network Management Cards  WEBCARDLX
Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications
PowerAlert Software For local monitoring via the UPS’s built-in communication ports and modify the UPS Power Strategy settings download PowerAlert Local software at https://www.tripplite.com/poweralert
Communications Cable USB and DB9 cabling included
WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
Network Management Card Description Network management card optional
Communications Interface Contact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)
LINE / BATTERY TRANSFER
Transfer Time No transfer time (0 ms.) in online, double-conversion mode
Low Voltage Transfer to Battery Power (Setpoint) 80V (100% load), 70V (66% load), 60V (33% load)
High Voltage Transfer to Battery Power (Setpoint) 150
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features Auto Probe Monitoring and Reboot (requires WEBCARDLX); Automatic inverter bypass; Expandable battery backup; Hot swappable batteries; On-Line/Double-Conversion; Remote management; Sine wave output; Surge/noise protection; Zero transfer time
Green Energy-Saving Features High efficiency economy mode operation; Individually controllable load banks; Schedulable daily hours of economy mode operation
Grounding Lug Includes back-panel grounding lug
STANDARDS & COMPLIANCE
Product Certifications CSA (Canada); NOM (Mexico); UL 1778
Product Compliance RoHS; ENERGY STAR Qualified; FCC Part 15 Class A (USA)
WARRANTY & SUPPORT
Product Warranty Period (Worldwide) 2-year limited warranty
Connected Equipment Insurance (U.S., Canada & Puerto Rico) $250,000 Ultimate Lifetime Insurance

Additional information

Weight 39.46 kg
Dimensions 24 × 59.99 × 75.99 cm
Brand