6000W APS X Series 48VDC 208/230V Inverter/Charger with Pure Sine-Wave Output, AVR, Hardwired
Description
Specifications
OVERVIEW
UPC Code | 037332137838 |
INPUT
Nominal Input Voltage(s) Supported | 208V AC; 230V AC |
Recommended Electrical Service | DC INPUT: Requires 48VDC input source capable of delivering 138A for the required duration (when used at full continuous capacity – DC requirements increase during OverPower and DoubleBoost operation). For automotive applications, professional hardwire installation with 250A minimum battery system fusing is recommended. |
Input Connection Type | DC INPUT: Set of DC bolt-down terminals. AC INPUT: Hardwire via built in terminal strip with cover plate |
Voltage Compatibility (VAC) | 208; 230 |
Voltage Compatibility (VDC) | 48 |
OUTPUT
Frequency Compatibility | 50 / 60 Hz |
Pure Sine Wave Output | Yes |
Output (Watts) | 6000 |
Nominal Output Voltage(s) Supported | 208V; 230V |
Output Receptacles | Hardwire |
Continuous Output Capacity (Watts) | 6000 |
Peak Output Capacity (Watts) | 12000 |
Output Voltage Regulation | LINE POWER (AC): Maintains 208/230V nominal sine wave output from line power source. INVERTER POWER (AC): Maintains sine wave output voltage of 208/230 VAC (+/-5%). |
Output Frequency Regulation | 50/60 Hz (+/- 0.3 Hz) |
BATTERY
Expandable Battery Runtime | Runtime is expandable with any number of user supplied wet or gel type batteries |
Expandable Runtime | Yes |
DC System Voltage (VDC) | 48 |
Battery Pack Accessory (Optional) | 98-121 sealed lead acid battery (optional) |
Battery Charge | Selectable 23 / 90 amp |
VOLTAGE REGULATION
Voltage Regulation Description | Includes automatic voltage regulation to correct brownouts and over-voltages back to usable levels |
Overvoltage Correction | Input voltages above 252V are automatically reduced by 9% (230V) / Input voltages above 235/245V are automatically reduced by 10% (208V) |
Brownout Correction | Input voltages from 208V -189V are automatically boosted by 11% (230V) / Input voltages from 188V-166V are automatically boosted 12% (208V) |
Severe Brownout Correction | Input voltages from 188V – 171V are automatically boosted by 26% (230V only) |
USER INTERFACE, ALERTS & CONTROLS
Front Panel LEDs | Set of 6 LEDs offer continuous status information on load percentage (6 levels reported) and battery charge level (7 levels reported). See manual for sequences. |
Switches | 3 position on/off/remote switch enables simple on/off power control plus “auto/remote” setting that enables distant on/off control of the inverter system when used in conjunction with optional APSRM4 accessory when used in inverter mode. In AC uninterruptible power mode, auto/remote setting enables automatic transfer from line power to battery power – to maintain continuous AC power to connected loads. Configuration dipswitches set unit voltage, frequency, transfer-time, battery type, and charger-related settings. |
PHYSICAL
Material of Construction | Metal |
Cooling Method | Dual multi-speed fans |
Form Factors Supported | Mounting slots enable permanent placement of inverter on any horizontal surface (see manual for additional mounting information) |
Shipping Dimensions (hwd / in.) | 16.00 x 14.50 x 23.25 |
Shipping Weight (lbs.) | 131.00 |
Unit Dimensions (hwd / in.) | 10 x 19.5 x 9 |
Unit Weight (lbs.) | 106.50 |
ENVIRONMENTAL
Relative Humidity | 0-95% non-condensing |
COMMUNICATIONS
SNMP Compatibility | Optional SNMPWEBSOLOHV accessory card enables remote monitoring of the unit via SNMP, SSH, telnet or Internet. |
Communications Interface | Contact closure; DB9 Serial |
LINE / BATTERY TRANSFER
Transfer Time (Line Power to Battery Mode) | Dip-switch selectable 20 millisecond (full cycle) / 10 millisecond (half-cycle) transfer times which are compatible with many computers, servers and networking equipment – verify transfer time compatibility of loads for UPS applications |
Low Voltage Transfer to Battery Power | In 230V AC “auto” mode, inverter/charger switches to battery mode as line voltage drops to 170V AC (user adjustable to 180V). In 208V AC “auto” mode, inverter/charger switches to battery mode as line voltage drops to 165V (user adjustable to 175V)-see manual |
High Voltage Transfer to Battery Power | In 230V AC “auto” mode, inverter/charger switches to battery mode as line voltage increases to 260V (user adjustable to 270 – see manual), In 208V AC “auto” mode, inverter/charger switches to battery mode as line voltage increases to 235V (user adjustable to 245V-see manual) |
FEATURES & SPECIFICATIONS
TVSS Grounding | Main grounding lug connects inverter/charger to earth or vehicle chassis ground |
Generator Start Compatibility | RJ-11 port connects to a generator with user-supplied cable to automatically cycle generator when battery level is low |
Battery Temperature Sensor | RJ-11 port connects to optional battery temperature sensor cable to regulate the charging system based on battery temperature |
STANDARDS & COMPLIANCE
Product Certifications | IEC/EN 62040 |
Product Compliance | RoHS; CE (Europe) |
WARRANTY & SUPPORT
Product Warranty Period (Worldwide) | 2-year limited warranty |
Additional information
Weight | 59.42 kg |
---|---|
Dimensions | 40.64 × 36.83 × 59.05 cm |
Brand |