120V 3000VA 2700W Double-Conversion UPS – 9 Outlets, Extended Run, WEBCARDLX, LCD, USB, DB9, 2U

Sale!

KShs659,277.58

120V 3000VA 2700W Double-Conversion UPS – 9 Outlets, Extended Run, WEBCARDLX, LCD, USB, DB9, 2U

Add to Wishlist
Add to Wishlist
Compare
SKU: SU3000RTXLCD2UN Category:

Description

Specifications

OVERVIEW
UPC Code 037332253552
UPS Type On-Line
INPUT
Rated input current (Maximum Load) 24A
Nominal Input Voltage(s) Supported 100V AC; 110V AC; 115V AC; 120V AC; 127V AC
Nominal Input Voltage Description 120V factory default
UPS Input Connection Type L5-30P
Input Circuit Breakers 40A
UPS Input Cord Length (ft.) 10
Recommended Electrical Service 30A 120V
Input Phase Single-Phase
OUTPUT
Output Volt Amp Capacity (VA) 3000
Output Capacity (kVA) 3
Output Watt Capacity (Watts) 2700
Output kW Capacity (kW) 2.7
Output Capacity Details ON LINE MODE: Maximum output capacity is reduced to 2430W (115V), 2295W (110V) and 2160W (100V); FREQUENCY REGULATION / CONVERSION MODE: Maximum output ratings are reduced in frequency regulation / conversion mode (127/120V 1890 watts / 115V 1701 watts / 110V 1606 watts / 100V 1512 watts). OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)
Power Factor 0.9
Crest Factor 3:1
Nominal Voltage Details 120V factory-default nominal voltage
Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
Frequency Compatibility Details ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY REGULATION / CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency input is 40 to 70Hz; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is regulated to +/-0.05Hz.
Output Voltage Regulation (Line Mode) +/- 2%
Output Voltage Regulation (Economy Line Mode) +/- 10%
Output Voltage Regulation (Battery Mode) +/- 3%
Load Management Receptacles Two switchable four-outlet load banks
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Nominal Output Voltage(s) Supported 100V; 110V; 115V; 120V; 127V
Output Receptacles (4) 5-15R; (4) 5-15/20R; (1) L5-30R
Individually Controllable Load Banks Yes
BATTERY
Battery Type Valve Regulated Lead Acid (VRLA)
Full Load Runtime (min.) 4.1 min. (2700w)
Half Load Runtime (min.) 11.3 min. (1350w)
Expandable Battery Runtime Extended runtime supported via optional external battery packs
Expandable Runtime Yes
Expandable Runtime Description Some external battery configurations require the use of Tripp Lite’s External Battery Configuration Software, see manual for details
External Battery Pack Compatibility  BP72V15-2U  (limit 1);  BP72V28RT-3U  (multi-pack compatible);  BP72V18-2US  (multi-pack compatible)
DC System Voltage (VDC) 72
Battery Recharge Rate (Included Batteries) Less than 3 hours recharge to 90% (typical, full load discharge)
Battery Access Front panel battery access
Internal UPS Replacement Battery Cartridge  RBC72S
Battery Replacement Description Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage Regulation Description Online, double-conversion power conditioning maintains 2% output voltage regulation during brownouts and overvoltages
Overvoltage Correction Corrects overvoltages to 150V (0-100% load)
Undervoltage Correction Corrects undervoltages to 90V at full load (90V at 100V nominal)
Severe Undervoltage Correction Corrects brownouts to 70V (70% load) & 55V (33% load)
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options
Switches 2 switches control off/on power status and alarm-cancel operation; 2 additional scroll-down and scroll-up / select options enable LCD status viewing and configuration options
Alarm Cancel Operation Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
Audible Alarm Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
LED Indicators 7 front panel LEDs indicate line power availability, AC to DC conversion, battery mode operation, inverter mode, eco mode operation, bypass mode operation and AC output status
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 570
UPS AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression Yes
PHYSICAL
Primary Form Factor Rackmount
Rack Height 2U
Cooling Method Fan
Included Mounting Accessory Description Includes 4 post rackmount installation accessories
Installation Form Factors Supported with Included Accessories 4 post 19 inch rackmount
Installation Form Factors Supported with Optional Accessories 2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM )
Minimum Required Rack Depth with External Battery Pack (cm) 80
Minimum Required Rack Depth with External Battery Pack (in.) 31.5
Minimum Required Rack Depth without External Battery Pack (cm) 79
Minimum Required Rack Depth without External Battery Pack (in.) 31
Primary UPS Depth (mm) 648
Primary UPS Height (mm) 86
Primary UPS Width (mm) 439
Shipping Dimensions (hwd / in.) 9.10 x 24.10 x 39.50
UPS Housing Material Steel
UPS Power Module Dimensions (hwd, in.) 3.4 x 17.3 x 25.5
UPS Power Module Weight (kg) 31.98
UPS Power Module Weight (lbs.) 70.5
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load) 801
AC Economy Mode BTU / Hr. (Full Load) 188
Battery Mode BTU / Hr. (Full Load) 1626
AC Economy Mode Efficiency Rating (100% Load) 98%
Operating Elevation (ft.) 0-3000m / 0-10,000 ft.
Audible Noise 50 dBA at 1m front side
Operating Elevation (m) 0 – 3000 m
COMMUNICATIONS
Network Management Cards  WEBCARDLX
Network Monitoring Port Description Includes pre-installed WEBCARDLX; DB9 port supports RS232 and contact closure communications; Economy-mode setting option is available using PowerAlert software and DB9 Serial cable connection OR installed Network Management Card
PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://www.tripplite.com/poweralert
Communications Cable USB and DB9 cabling included
WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
Network Management Card Description Network management card included
Communications Interface Contact closure; DB9 Serial; EPO (emergency power off); Pre-installed network card; Slot for SNMP/Web interface; USB (HID enabled)
LINE / BATTERY TRANSFER
Transfer Time Zero (0 milliseconds) in double-conversion mode; 4 milliseconds economy mode
Low Voltage Transfer to Battery Power (Setpoint) 55V at 33% load, 70V at 70% load, 100V at 100% load (90V full load at 100V nominal setting)
High Voltage Transfer to Battery Power (Setpoint) 150
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features Auto Probe Monitoring and Reboot (included); Automatic inverter bypass; Expandable battery backup; Hot swappable batteries; On-Line/Double-Conversion; Remote management; Sine wave output; Surge/noise protection; Zero transfer time
Green Energy-Saving Features High efficiency economy mode operation; Individually controllable load banks; Schedulable daily hours of economy mode operation
STANDARDS & COMPLIANCE
Product Certifications CSA (Canada); NOM (Mexico); UL 1778
Product Compliance RoHS; FCC Part 15 Class A (USA)
WARRANTY & SUPPORT
Product Warranty Period (Worldwide) 2-year limited warranty
Connected Equipment Insurance (U.S., Canada & Puerto Rico) $250,000 Ultimate Lifetime Insurance

Additional information

Weight 41.73 kg
Dimensions 23.11 × 61.21 × 100.33 cm
Brand