			$2,315.60
120V 750VA 675W Double-Conversion UPS – 6 Outlets, Extended Run, WEBCARDLX, LCD, USB, DB9, 2U Rack/Tower
Description
Specifications
OVERVIEW
| UPC Code | 037332253538 | 
| UPS Type | On-Line | 
INPUT
| Rated input current (Maximum Load) | 8A | 
| Nominal Input Voltage(s) Supported | 100V AC; 110V AC; 115V AC; 120V AC; 127V AC | 
| Nominal Input Voltage Description | 120V factory default | 
| UPS Input Connection Type | 5-15P | 
| Input Circuit Breakers | 15A | 
| UPS Input Cord Length (ft.) | 10 | 
| Recommended Electrical Service | 15A 120V | 
| Input Phase | Single-Phase | 
OUTPUT
| Output Volt Amp Capacity (VA) | 750 | 
| Output Capacity (kVA) | 0.75 | 
| Output Watt Capacity (Watts) | 675 | 
| Output Capacity Details | ON LINE MODE: Maximum output capacity is reduced to 608 watts at 100V nominal; FREQUENCY CONVERSION MODE: Maximum output ratings are reduced in frequency regulation / conversion mode (127/120/115/110V: 472 watts / 100V: 425 watts) OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits) | 
| Power Factor | 0.9 | 
| Crest Factor | 3:1 | 
| Nominal Voltage Details | 120V factory-default nominal voltage | 
| Frequency Compatibility | 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion | 
| Frequency Compatibility Details | ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY REGULATION / CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency input is 40 to 70Hz; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is regulated to +/-0.05Hz. | 
| Output Voltage Regulation (Line Mode) | +/- 2% | 
| Output Voltage Regulation (Economy Line Mode) | +/- 10% | 
| Output Voltage Regulation (Battery Mode) | +/- 3% | 
| Load Management Receptacles | Two switchable single-outlet 5-15R load banks | 
| Output AC Waveform (AC Mode) | Pure Sine wave | 
| Output AC Waveform (Battery Mode) | Pure Sine wave | 
| Nominal Output Voltage(s) Supported | 100V; 110V; 115V; 120V; 127V | 
| Output Receptacles | (6) 5-15R | 
| Individually Controllable Load Banks | Yes | 
BATTERY
| Battery Type | Valve Regulated Lead Acid (VRLA) | 
| Full Load Runtime (min.) | 4.3 min. (675w) | 
| Half Load Runtime (min.) | 13.9 min. (337.5w) | 
| Expandable Battery Runtime | Extended runtime supported via optional external battery packs | 
| Expandable Runtime | Yes | 
| Expandable Runtime Description | Some external battery configurations require the use of Tripp Lite’s External Battery Configuration Software, see manual for details | 
| External Battery Pack Compatibility | BP24V15RT2U (limit 1); BP24V28-2U (limit 1); BP24V70-3U (multi-pack compatible); BP24V36-2US (multi-pack compatible) | 
| DC System Voltage (VDC) | 24 | 
| Battery Recharge Rate (Included Batteries) | Less than 3 hours recharge to 90% (typical, full load discharge) | 
| Battery Access | Front panel battery access | 
| Internal UPS Replacement Battery Cartridge | RBC24V-LCD | 
| Battery Replacement Description | Hot-swappable, user replaceable batteries | 
VOLTAGE REGULATION
| Voltage Regulation Description | Online, double-conversion power conditioning maintains 2% output voltage regulation during brownouts and overvoltages | 
| Overvoltage Correction | Corrects overvoltages to 150V (0-100% load) | 
| Undervoltage Correction | Corrects undervoltages to 100V at full load (90V at 100V nominal) | 
| Severe Undervoltage Correction | Corrects brownouts to 70V (70% load) & 55V (33% load) | 
USER INTERFACE, ALERTS & CONTROLS
| Front Panel LCD Display | Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options | 
| Switches | 2 switches control off/on power status and alarm-cancel operation; 2 additional scroll-down and scroll-up / select options enable LCD status viewing and configuration options | 
| Alarm Cancel Operation | Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available | 
| Audible Alarm | Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions | 
| LED Indicators | 7 front panel LEDs indicate line power availability, AC to DC conversion, battery mode operation, inverter mode, eco mode operation, bypass mode operation and AC output status | 
SURGE / NOISE SUPPRESSION
| UPS AC Suppression Joule Rating | 570 | 
| UPS AC Suppression Response Time | Instantaneous | 
| UPS Dataline Suppression | 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet | 
| EMI / RFI AC Noise Suppression | Yes | 
PHYSICAL
| Primary Form Factor | Rackmount | 
| Rack Height | 2U | 
| Cooling Method | Fan | 
| Included Mounting Accessory Description | Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm) | 
| Installation Form Factors Supported with Included Accessories | 4 post 19 inch rackmount | 
| Installation Form Factors Supported with Optional Accessories | 2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM ) | 
| Minimum Required Rack Depth (inches) | 15.5 | 
| Optional Mounting Accessory Notes | Optional 2-9USTAND enables upright tower UPS placement; 2POSTRMKITWM enables wall-mount and 2-post rackmount installation; 4POSTRAILKITWM enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm); UPSHDEARKIT enables installation in 2 or 4-post racks using front vertical rails only, without rear support | 
| Primary UPS Depth (mm) | 318 | 
| Primary UPS Height (mm) | 89 | 
| Primary UPS Width (mm) | 445 | 
| Shipping Dimensions (hwd / in.) | 9.00 x 23.10 x 19.40 | 
| UPS Housing Material | Steel | 
| UPS Power Module Dimensions (hwd, in.) | 3.5 x 17.5 x 12.5 | 
| UPS Power Module Weight (kg) | 12.52 | 
| UPS Power Module Weight (lbs.) | 27.6 | 
ENVIRONMENTAL
| Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius | 
| Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius | 
| Relative Humidity | 0 to 95%, non-condensing | 
| AC Mode BTU / Hr. (Full Load) | 256 | 
| AC Economy Mode BTU / Hr. (Full Load) | 173 | 
| Battery Mode BTU / Hr. (Full Load) | 439 | 
| AC Economy Mode Efficiency Rating (100% Load) | 93% | 
| Operating Elevation (ft.) | 0-3000m / 0-10,000 ft. | 
| Audible Noise | 45 dBA at 1m front side | 
| Operating Elevation (m) | 0 – 3000 m | 
COMMUNICATIONS
| Network Management Cards | WEBCARDLX | 
| Network Monitoring Port Description | Includes pre-installed WEBCARDLX Network Management Card; Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications | 
| PowerAlert Software | For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://www.tripplite.com/poweralert | 
| Communications Cable | USB and DB9 cabling included | 
| WatchDog Compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications | 
| Network Management Card Description | Network management card included | 
| Communications Interface | Contact closure; DB9 Serial; EPO (emergency power off); Pre-installed network card; Slot for SNMP/Web interface; USB (HID enabled) | 
LINE / BATTERY TRANSFER
| Transfer Time | Zero (0 milliseconds) in double-conversion mode; 4 milliseconds economy mode | 
| Low Voltage Transfer to Battery Power (Setpoint) | 100V at full load (90V full load at 100V nominal setting); 70V at 70% load; 55V at 33% load | 
| High Voltage Transfer to Battery Power (Setpoint) | 150 | 
FEATURES & SPECIFICATIONS
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported | 
| High Availability UPS Features | Auto Probe Monitoring and Reboot (included); Automatic inverter bypass; Expandable battery backup; Hot swappable batteries; On-Line/Double-Conversion; Remote management; Sine wave output; Surge/noise protection; Zero transfer time | 
| Green Energy-Saving Features | High efficiency economy mode operation; Individually controllable load banks; Schedulable daily hours of economy mode operation | 
STANDARDS & COMPLIANCE
| Product Certifications | CSA (Canada); UL 1778 | 
| Product Compliance | RoHS; FCC Part 15 Class B (USA) | 
WARRANTY & SUPPORT
| Product Warranty Period (Worldwide) | 2-year limited warranty | 
| Connected Equipment Insurance (U.S., Canada & Puerto Rico) | $250,000 Ultimate Lifetime Insurance | 
Additional information
| Weight | 18.14 kg | 
|---|---|
| Dimensions | 22.86 × 58.67 × 49.27 cm | 
| Brand | 