Specifications

OVERVIEW
UPC Code 037332185648
UPS Type On-Line
INPUT
Rated input current (Maximum Load) 4.99A
Nominal Input Voltage(s) Supported 200V AC; 208V AC; 220V AC; 230V AC; 240V AC
UPS Input Connection Type C14 inlet
Input Phase Single-Phase
OUTPUT
Output Volt Amp Capacity (VA) 1000
Output Capacity (kVA) 1
Output Watt Capacity (Watts) 900
Output kW Capacity (kW) 0.9
Output Capacity Details DE-RATING INFORMATION: Max output in Frequency Conversion mode is reduced to 630 watts for 208/220/230/240V output voltages; Max output is 720W (504W in Frequency Conversion mode) at 200V output voltage OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% for 3 minutes, 150% for 30 seconds and >150% for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits).
Power Factor 0,9
Crest Factor 3:1
Nominal Voltage Details Nominal output voltage is user configured on first power-on
Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
Frequency Compatibility Details Output frequency matches input nominal on startup; Output capacity de-rates by 30% during frequency conversion operation
Output Voltage Regulation (Line Mode) +/- 2%
Output Voltage Regulation (Economy Line Mode) +/- 10%
Output Voltage Regulation (Battery Mode) +/- 2%
Included Output Power Cables Includes 2 C13 to C14 power cables
Load Management Receptacles Two switchable 2-outlet load banks
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Nominal Output Voltage(s) Supported 200V; 208V; 220V; 230V; 240V
Output Receptacles (6) C13
Individually Controllable Load Banks Yes
BATTERY
Battery Type Valve Regulated Lead Acid (VRLA)
Full Load Runtime (min.) 4.7 min. (900w)
Half Load Runtime (min.) 12.3 min. (450w)
Expandable Battery Runtime Supports extended runtime with optional external battery packs
Expandable Runtime Yes
External Battery Pack Compatibility  BP24V15RT2U  (limit 1);  BP24V28-2U  (limit 1);  BP24V36-2US  (multi-pack compatible);  BP24V70-3U  (multi-pack compatible)
DC System Voltage (VDC) 24
Battery Recharge Rate (Included Batteries) Less than 4.1 hours from 10% to 90% (typical, full load discharge)
Battery Access Front panel battery access door
Internal UPS Replacement Battery Cartridge  RBC24S
Battery Replacement Description Hot-swappable, replaceable batteries
VOLTAGE REGULATION
Voltage Regulation Description Online, double-conversion power conditioning
Overvoltage Correction 2% output voltage regulation during overvoltages to 288V
Undervoltage Correction 2% output voltage regulation during undervoltages to 160V (100% load), 130V (70% load), 100V (30% load)
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display Interactive front-panel LCD interface reports UPS operating mode, detailed UPS status and site-power information; LCD interface also enables a variety of advanced UPS setup and configuration options
Switches 5 front panel switches: On/Off, Up, Down and Escape
Alarm Cancel Operation Power-fail alarm can be silenced by following on-screen prompts
Audible Alarm Audible alarm indicates power failure, low battery, overload and fault
LED Indicators 4 front panel LEDs: AC input (green), AC output (green), Battery (yellow), Fault (red)
SURGE / NOISE SUPPRESSION
UPS Dataline Suppression Details Single line dialup / network dataline protection included
EMI / RFI AC Noise Suppression Yes
AC Suppression Joule Rating 627
AC Suppression Response Time Instantaneous
PHYSICAL
Primary Form Factor Rackmount
Rack Height 2U
Cooling Method Fan
Included Mounting Accessory Description Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)
Installation Form Factors Supported with Included Accessories 4 post 19 inch rackmount
Installation Form Factors Supported with Optional Accessories 2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM )
Minimum Required Rack Depth with External Battery Pack (cm) 48
Minimum Required Rack Depth with External Battery Pack (in.) 18.75
Minimum Required Rack Depth without External Battery Pack (cm) 46
Minimum Required Rack Depth without External Battery Pack (in.) 18
Optional Mounting Accessory Notes Optional  2-9USTAND  enables upright tower UPS placement;  2POSTRMKITWM  enables wall-mount and 2-post rackmount installation;  4POSTRAILKITWM  enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm);  UPSHDEARKIT  enables installation in 2 or 4-post racks using front vertical rails only, without rear support
Primary UPS Depth (mm) 397
Primary UPS Height (mm) 88
Primary UPS Width (mm) 438
Shipping Dimensions (hwd / in.) 9.60 x 19.80 x 23.50
Shipping Weight (lbs.) 44.00
UPS Housing Material Metal
UPS Power Module Dimensions (hwd, in.) 3.46 x 17.24 x 15.63
UPS Power Module Weight (kg) 12.70
UPS Power Module Weight (lbs.) 28
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
Relative Humidity 5 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load) 245
AC Economy Mode BTU / Hr. (Full Load) 128
Battery Mode BTU / Hr. (Full Load) 500
AC Mode Efficiency Rating (100% Load) >93%
AC Economy Mode Efficiency Rating (100% Load) >96%
Audible Noise <45dB at front side 1M
Operating Elevation (m) Up to 3000m
COMMUNICATIONS
Network Management Cards  WEBCARDLX
PowerAlert Software Available for download at www.tripplite.com
Communications Cable USB and DB9 cabling included
WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
Network Management Card Description Network management card optional
Communications Interface Contact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)
LINE / BATTERY TRANSFER
Transfer Time No transfer time (0 ms.) in online, double-conversion mode; 3-9 ms. transfer time during economy mode operation
Low Voltage Transfer to Battery Power (Setpoint) 160V (100% load), 140V (66% load), 120V (33% load)
High Voltage Transfer to Battery Power (Setpoint) 288V
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features Auto Probe Monitoring and Reboot (requires WEBCARDLX); Automatic inverter bypass; Expandable battery backup; Hot swappable batteries; On-Line/Double-Conversion; Remote management; Sine wave output; Surge/noise protection; Zero transfer time
Green Energy-Saving Features High efficiency economy mode operation; Individually controllable load banks
Grounding Lug Back panel grounding lug included
STANDARDS & COMPLIANCE
Product Certifications CSA (Canada); NOM (Mexico); UL 1778
Product Compliance RoHS; SASO (Saudi Arabia); CE (Europe); EAC (Belarus, Kazakhstan, Russia); ENERGY STAR Qualified
WARRANTY & SUPPORT
Product Warranty Period (Worldwide) 2-year limited warranty
Connected Equipment Insurance (U.S., Canada & Puerto Rico) $250,000 Ultimate Lifetime Insurance

Additional information

Weight 19.95 kg
Dimensions 24.38 × 50.29 × 59.69 cm
Brand