| UPC Code | 037332185631 | 
| UPS Type | On-Line | 
INPUT
| Rated input current (Maximum Load) | 14.97A | 
| Nominal Input Voltage(s) Supported | 200V AC; 208V AC; 220V AC; 230V AC; 240V AC | 
| UPS Input Connection Type | C20 inlet | 
| Input Phase | Single-Phase | 
OUTPUT
| Output Volt Amp Capacity (VA) | 3000 | 
| Output Capacity (kVA) | 3 | 
| Output Watt Capacity (Watts) | 2700 | 
| Output kW Capacity (kW) | 2.7 | 
| Output Capacity Details | DE-RATING INFORMATION: Max output in Frequency Conversion mode is reduced to 1890 watts for 208/220/230/240V output voltages; Max output is reduced to 2160W at 200V output voltage in all operating modes OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% for 3 minutes, 150% for 30 seconds and >150% for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits). | 
| Power Factor | 0.9 | 
| Crest Factor | 3:1 | 
| Nominal Voltage Details | Nominal output voltage is user configured on first power-on | 
| Frequency Compatibility | 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion | 
| Frequency Compatibility Details | Output frequency matches input nominal on startup; Output capacity de-rates by 30% during frequency conversion operation | 
| Output Voltage Regulation (Line Mode) | +/- 2% | 
| Output Voltage Regulation (Economy Line Mode) | +/- 10% | 
| Output Voltage Regulation (Battery Mode) | +/- 2% | 
| Included Output Power Cables | Includes 2 C13 to C14 and 1 C19 to C20 power cables | 
| Load Management Receptacles | Two switchable 4 outlet load banks (3 C13 and 1 C19 per bank) | 
| Output AC Waveform (AC Mode) | Pure Sine wave | 
| Output AC Waveform (Battery Mode) | Pure Sine wave | 
| Nominal Output Voltage(s) Supported | 200V; 208V; 220V; 230V; 240V | 
| Output Receptacles | (8) C13; (2) C19 | 
| Individually Controllable Load Banks | Yes | 
BATTERY
| Battery Type | Valve Regulated Lead Acid (VRLA) | 
| Full Load Runtime (min.) | 5 min. (2700w) | 
| Half Load Runtime (min.) | 13.5 min. (1350w) | 
| Expandable Battery Runtime | Supports extended runtime with optional external battery packs | 
| Expandable Runtime | Yes | 
| External Battery Pack Compatibility | BP72V15-2U (limit 1); BP72V28RT-3U (multi-pack compatible); BP72V18-2US (multi-pack compatible) | 
| DC System Voltage (VDC) | 72 | 
| Battery Recharge Rate (Included Batteries) | 3.0 hours from 10% to 90% (typical, full load discharge) | 
| Battery Access | Front panel battery access door | 
| Internal UPS Replacement Battery Cartridge | RBC72S | 
| Battery Replacement Description | Hot-swappable, replaceable batteries | 
VOLTAGE REGULATION
| Voltage Regulation Description | Online, double-conversion power conditioning | 
| Overvoltage Correction | 2% output voltage regulation during overvoltages to 288 | 
| Undervoltage Correction | 2% output voltage regulation during undervoltages to 160V (100% load), 130V (70% load), 100V (30% load) | 
USER INTERFACE, ALERTS & CONTROLS
| Front Panel LCD Display | Interactive front-panel LCD interface reports UPS operating mode, detailed UPS status and site-power information; LCD interface also enables a variety of advanced UPS setup and configuration options | 
| Switches | 5 front panel switches: On/Off, Up, Down and Escape | 
| Alarm Cancel Operation | Power-fail alarm can be silenced by following on-screen prompts | 
| Audible Alarm | Audible alarm indicates power failure, low battery, overload and fault | 
| LED Indicators | 4 front panel LEDs: AC input (green), AC output (green), Battery (yellow), Fault (red) | 
SURGE / NOISE SUPPRESSION
| UPS Dataline Suppression Details | Single line dialup / network dataline protection included | 
| EMI / RFI AC Noise Suppression | Yes | 
| AC Suppression Joule Rating | 570 | 
| AC Suppression Response Time | Instantaneous | 
PHYSICAL
| Primary Form Factor | Rackmount | 
| Rack Height | 2U | 
| Cooling Method | Fan | 
| Included Mounting Accessory Description | 4 post installation accessories included | 
| Installation Form Factors Supported with Included Accessories | 4 post 19 inch rackmount | 
| Installation Form Factors Supported with Optional Accessories | 2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); Tower ( 2-9USTAND ) | 
| Minimum Required Rack Depth with External Battery Pack (cm) | 77 | 
| Minimum Required Rack Depth with External Battery Pack (in.) | 30.25 | 
| Minimum Required Rack Depth without External Battery Pack (cm) | 70 | 
| Minimum Required Rack Depth without External Battery Pack (in.) | 27.75 | 
| Primary UPS Depth (mm) | 616 | 
| Primary UPS Height (mm) | 88 | 
| Primary UPS Width (mm) | 438 | 
| Shipping Dimensions (hwd / in.) | 9.45 x 23.62 x 29.92 | 
| Shipping Weight (lbs.) | 86.00 | 
| UPS Housing Material | Metal | 
| UPS Power Module Dimensions (hwd, in.) | 3.46 x 17.24 x 24.25 | 
| UPS Power Module Weight (kg) | 31.17 | 
| UPS Power Module Weight (lbs.) | 68.72 | 
ENVIRONMENTAL
| Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius. | 
| Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius. | 
| Relative Humidity | 5 to 95%, non-condensing | 
| AC Mode BTU / Hr. (Full Load) | 933 | 
| AC Economy Mode BTU / Hr. (Full Load) | 485 | 
| Battery Mode BTU / Hr. (Full Load) | 1399 | 
| AC Mode Efficiency Rating (100% Load) | >90% | 
| AC Economy Mode Efficiency Rating (100% Load) | >95% | 
| Audible Noise | <50dB at front side 1M | 
| Operating Elevation (m) | Up to 3000m | 
COMMUNICATIONS
| Network Management Cards | SNMPWEBCARD; WEBCARDLX | 
| PowerAlert Software | For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://www.tripplite.com/poweralert | 
| Communications Cable | USB and DB9 cabling included | 
| WatchDog Compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications | 
| Network Management Card Description | Network management card optional | 
| Communications Interface | Contact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled) | 
LINE / BATTERY TRANSFER
| Transfer Time | No transfer time (0 ms.) in online, double-conversion mode; 4 ms. transfer time during economy mode operation | 
| Low Voltage Transfer to Battery Power (Setpoint) | 160V (100% load), 140V (66% load), 120V (33% load) | 
| High Voltage Transfer to Battery Power (Setpoint) | 288V | 
FEATURES & SPECIFICATIONS
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported | 
| High Availability UPS Features | Auto Probe Monitoring and Reboot (requires WEBCARDLX); Automatic inverter bypass; Expandable battery backup; Hot swappable batteries; On-Line/Double-Conversion; Remote management; Sine wave output; Surge/noise protection; Zero transfer time | 
| Green Energy-Saving Features | High efficiency economy mode operation; Individually controllable load banks | 
| Grounding Lug | Back panel grounding lug included | 
STANDARDS & COMPLIANCE
| Product Certifications | CSA (Canada); UL 1778 | 
| Product Compliance | RoHS; SASO (Saudi Arabia); CE (Europe); EAC (Belarus, Kazakhstan, Russia); ENERGY STAR Qualified; FCC Part 15 Class A (USA) | 
WARRANTY & SUPPORT
| Product Warranty Period (Worldwide) | 2-year limited warranty | 
| Connected Equipment Insurance (U.S., Canada & Puerto Rico) | $250,000 Ultimate Lifetime Insurance | 
Additional information
| Weight | 96 kg | 
|---|---|
| Dimensions | 24 × 59.99 × 75.99 cm | 
| Brand | 