208/240V 6000VA 6000W On-Line UPS, Unity Power Factor, Hardwire/L6-30P Input, 3U

Sale!

KShs1,285,654.76

208/240V 6000VA 6000W On-Line UPS, Unity Power Factor, Hardwire/L6-30P Input, 3U

Add to Wishlist
Add to Wishlist
Compare
SKU: SU6KRT3UHV Category:

Description

Specifications

OVERVIEW
UPC Code 037332177414
UPS Type On-Line
INPUT
Rated input current (Maximum Load) Hardwire AC input: 32A (200V), 30.7A (208V), 26.6A (240V) maximum; With included NEMA L6-30P input: 24A (200/208/240V) maximum; Max inrush current: 100A
Nominal Input Voltage(s) Supported 200V AC; 208V AC; 240V AC
Nominal Input Voltage Description 208V factory default
UPS Input Connection Type Hardwire; L6-30P
UPS Input Connection Description Hardwire input supports 3 wire L1, L2/N, PE(GND) input configurations; Includes optional L6-30P input cable
Input Phase Single-Phase
Input Frequency 50 / 60 Hz
Input Cord Length (ft.) 10
Power Factor (Input) 0.98 minimum (full load, nominal input voltage)
THDi <8% full load; <10% half load
OUTPUT
Output Volt Amp Capacity (VA) 6000
Output Capacity (kVA) 6
Output Watt Capacity (Watts) 6000
Output kW Capacity (kW) 6
Output Capacity Details Supports 6000VA / 6000W with hardwire AC input; Maximum output capacity de-rates to 5600W (240V) / 4800W (208V) / 4600W (200V) when used with included L6-30P AC input cord; Inverter supports up to 104% load continuously, Up to 125% / 150% for 1.0 / 0.5 min. before bypass transfer (when available) or shutdown; Loads greater than 150% trigger immediate shutdown; AC TRANSIENT RESPONSE: ±1.5% RMS of initial value (between 10% & 90% load step)
Power Factor 1.0
Crest Factor 3:1 maximum
Nominal Voltage Details Nominal output voltage selection is available via front panel LCD interface; 200/208/240V recommended
Frequency Compatibility 50 / 60 Hz
Frequency Compatibility Details MAX-QUALITY/MAX-EFFICIENCY/AUTO-ADAPTIVE MODES: Output frequency matches input nominal on startup and tracks input frequency up to ±3Hz of nominal; When input frequency is greater than ±3Hz of nominal, output frequency is inverter regulated to ±0.5Hz of nominal; BATTERY MODE: Output frequency is inverter regulated to ±0.5Hz of the configured nominal output frequency; FREQUENCY CONVERSION MODE: Output is inverter regulated to the selected 50/60Hz output setting with ±0.5Hz regulation (de-rates to 70% capacity, bypass not available); FREQUENCY REGULATION MODE: Enables frequency correction to ±0.5Hz of the frequency sensed by the UPS on startup (no de-rating, bypass is available when input frequency is within ±0.5Hz of output)
Load Management Receptacles Three built-in switchable output load banks; BANK 1 (Set of 2 L6-30R outlets); BANK 2 (Set of 2 L6-20R outlets); BANK 3 (Set of 2 L6-20R outlets)
Output Circuit Breakers 30A double-pole breaker protects 2 L6-30R outlets; 20A double-pole breaker protects 4 L6-20R outlets
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Nominal Output Voltage(s) Supported 200V; 208V; 220V; 230V; 240V
Output Receptacles Hardwire; (4) L6-20R; (2) L6-30R
Output Voltage Regulation ±1% Inverter output; ±10% Economy mode; ±15% Bypass mode (configurable from ±5% to ±20%); Output voltage THD <2% (full load) / <3% (half load)
Individually Controllable Load Banks Yes
BATTERY
Battery Type Valve Regulated Lead Acid (VRLA)
Full Load Runtime (min.) 3 minutes (6000 watts)
Half Load Runtime (min.) 8.5 minutes (3000 watts)
Expandable Battery Runtime Runtime is expandable with external battery packs
Expandable Runtime Yes
Expandable Runtime Description Up to 4 external battery packs with sensor cabling are automatically sensed and configured for advanced temperature controlled charging and accurate runtime reporting; Configurations using 5-10 external battery packs are supported, but may require the use of Tripp Lite’s EXTERNAL BATTERY CONFIGURATION software for for full integration
External Battery Pack Compatibility  BP192V12RT3US
DC System Voltage (VDC) 192
Battery Recharge Rate (Included Batteries) 3 hours from 10% to 90% (typical, internal batteries with full load discharge); Charge settings: 1.5A (internal batteries) / 2A (with external battery packs) configures automatically; Supports temperature compensated battery charging
Battery Access Front panel battery access door
Internal UPS Replacement Battery Cartridge  RBC58-3US  (qty 1)
Battery Replacement Description Hot-swappable, user replaceable internal batteries and external battery packs
VOLTAGE REGULATION
Voltage Regulation Description ±1% Inverter output regulation; ±10% in optional Eco mode
Overvoltage Correction Corrects overvoltages as high as 275V
Undervoltage Correction Corrects undervoltages as low as 156V (100% load) / 100V (50% load); derates linearly
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display Selectable LCD display with Escape, Page Up, Page Down, Enter and Power buttons enable UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats (see manual)
Switches Includes main power off/on switch, plus Up, Down, Enter and Esc switches to set and execute LCD functions.
Alarm Cancel Operation Alarm cancel switch
Audible Alarm Unique audible alarms for all major UPS, environmental and power conditions (see manual)
LED Indicators 4 front-panel LEDs indicate AC input, AC output, Battery mode and Fault conditions
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 1680
UPS AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression Yes
PHYSICAL
Primary Form Factor Rackmount
Rack Height 3U
Cooling Method Load and thermal controlled cooling fans; Field-replaceable (92mm x 38mm, ball-bearing, 115 CFM)
Included Mounting Accessory Description Includes 4 post rackmount installation accessories; Included mounting brackets support front-to-rear rail distances of 520 to 914.4mm (20.5 to 36 in.); Enclosures require a minimum depth of 818 mm (32.2 in.) from the front rails to the closed rear door
Installation Form Factors Supported with Included Accessories 4 post 19 inch rackmount
Installation Form Factors Supported with Optional Accessories 2 post rackmount ( 2POSTRMKITHD ); Tower ( 2-9USTAND )
Minimum Required Rack Depth (inches) 32
Primary UPS Depth (mm) 762
Primary UPS Height (mm) 131
Primary UPS Width (mm) 445
Shipping Dimensions (hwd / in.) 6.89 x 23.70 x 33.35
Unit Dimension Details Minimum required rack depth assumes 127mm / 5 in. additional depth for AC input/output cabling; See submittal drawing for additional dimension detail
UPS Housing Material Sheet metal
UPS Power Module Dimensions (hwd, in.) 5.14 x 17.5 x 30
UPS Power Module Weight (kg) 56.79
UPS Power Module Weight (lbs.) 125.2
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 5 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load) 1300
AC Mode Efficiency Rating (100% Load) >94%
AC Economy Mode Efficiency Rating (100% Load) >98%
Operating Elevation (ft.) Up to 6562 ft.
Audible Noise 67.1dB (full load) / 53dB (no load) front side 1m
Operating Elevation (m) Up to 2000m
COMMUNICATIONS
Network Management Cards  WEBCARDLXMINI
Network Monitoring Port Description Includes Pre-installed WEBCARDLXMINI network management card; DB9 port supports RS-232 and Contact-closure signaling
PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://www.tripplite.com/poweralert
Communications Cable USB, DB9 serial and EPO cables included
WatchDog Compatibility Yes
Network Management Card Description Network management card included
Communications Interface Contact closure; DB9 Serial; EPO (emergency power off); Pre-installed network card; Slot for SNMP/Web interface; USB (HID enabled)
LINE / BATTERY TRANSFER
Transfer Time Online to Battery mode: 0 ms. (Zero transfer time)
Transfer Time (Economy Mode) Online to Eco mode: 2 milliseconds / Eco to Battery mode: 8 milliseconds
Low Voltage Transfer to Battery Power (Setpoint) 156V (full load) / 100V (50% load or less, derates linearly)
High Voltage Transfer to Battery Power (Setpoint) 275V
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features Auto Probe Monitoring and Reboot (requires WEBCARDLXMINI); Automatic inverter bypass; Hot swappable batteries; On-Line/Double-Conversion; Surge/noise protection; Zero transfer time
Green Energy-Saving Features High efficiency economy mode operation; Individually controllable load banks; Schedulable daily hours of economy mode operation; Support for daily startup and shutoff
STANDARDS & COMPLIANCE
Product Certifications RETIE (Colombia); CSA (Canada); NOM (Mexico); UL 1778
Product Compliance RoHS; ENERGY STAR Qualified; FCC Part 15 Class A (USA)
WARRANTY & SUPPORT
Product Warranty Period (Worldwide) 2-year limited warranty
Connected Equipment Insurance (U.S., Canada & Puerto Rico) $250,000 Ultimate Lifetime Insurance

Additional information

Weight 74.16 kg
Dimensions 17.5 × 60.19 × 84.7 cm
Brand