OVERVIEW
UPC Code 037332141330
UPS Type On-Line
INPUT
Nominal Input Voltage(s) Supported 120/208V 3-PH Wye
Nominal Input Voltage Description 3-Phase Wye, 4 wire (L1, L2, L3, N, G)
UPS Input Connection Type Hardwire
Input Phase 3-Phase
OUTPUT
Output Volt Amp Capacity (VA) 80000
Output Capacity (kVA) 80
Output Watt Capacity (Watts) 64000
Output kW Capacity (kW) 64
Power Factor 0.8
Crest Factor 3:1
Frequency Compatibility 50 / 60 Hz
Output Voltage Regulation (Line Mode) +/-1%
Output Voltage Regulation (Battery Mode) +/-1%
Output AC Waveform (AC Mode) Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Nominal Output Voltage(s) Supported 120/208V 3-PH Wye
Output Receptacles Hardwire
Individually Controllable Load Banks No
BATTERY
Expandable Battery Runtime Battery set sold separate
Expandable Runtime Yes
Expandable Runtime Description External battery pack wiring is contractor supplied
External Battery Pack Compatibility  BP480V200 ;  BP480V300 ;  BP480V400 ; BP480V40C;  BP480V500
DC System Voltage (VDC) +/- 240VDC
Battery Recharge Rate (Included Batteries) 2 – 4 hours from 10% to 90%
Battery Replacement Description Hot-swappable, replaceable batteries
VOLTAGE REGULATION
Voltage Regulation Description Online, double-conversion power conditioning
Overvoltage Correction Maintains continuous operation without using battery power during overvoltages to 150 / 260 (3-Phase, 4-Wire, wye), reducing output within 1% of nominal
Undervoltage Correction Maintains continuous operation without using battery power during brownout / undervoltage conditions to 94 / 163 (3-Phase, 4-Wire, wye)
USER INTERFACE, ALERTS & CONTROLS
Switches ON button turns UPS’s inverter ON. OFF button turns UPS’s inverter OFF. LCD Display Control Buttons browses through and selects items displayed on LCD screen. Emergency Power Off button turns UPS output OFF and disables Bypass output. Manual Bypass breaker bypasses the UPS’s inverter during maintenance.
Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch
Audible Alarm Alarms warn against a variety of operational conditions: low-battery, overload, shutdown, bypass and more
LED Indicators 4-LED Display: Displays normal AC input, on battery power, bypass input and fault conditions
SURGE / NOISE SUPPRESSION
EMI / RFI AC Noise Suppression Yes
AC Suppression Joule Rating 4675
AC Suppression Response Time Instantaneous
PHYSICAL
Primary Form Factor Tower
Cooling Method Fans
Installation Form Factors Supported with Included Accessories Tower
Primary UPS Depth (mm) 986
Primary UPS Height (mm) 1,697
Primary UPS Width (mm) 521
Shipping Dimensions (hwd / in.) 75.00 x 28.50 x 48.00
Shipping Weight (lbs.) 1642.50
UPS Housing Material Steel
UPS Power Module Dimensions (hwd, in.) 66.8 x 20.5 x 38.8
UPS Power Module Weight (kg) 654.99
UPS Power Module Weight (lbs.) 1444
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load) 18665
Battery Mode BTU / Hr. (Full Load) 19005
COMMUNICATIONS
Network Management Cards SNMPWEBCARD;  TLNETCARD ;  WEBCARDLX ;  MODBUSCARD ;  RELAYIOCARD
PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://www.tripplite.com/poweralert
Communications Cable DB9 cabling included
Communications Interface DB9 Serial; Slot for SNMP/Web interface
LINE / BATTERY TRANSFER
Transfer Time No transfer time (0 ms.) in online, double-conversion mode
Low Voltage Transfer to Battery Power (Setpoint) Maintains continuous operation during undervoltages as low as 94 / 163V AC (3-Phase, 4-Wire, wye). Below this point, output is maintained utilizing battery reserves.
High Voltage Transfer to Battery Power (Setpoint) Maintains continuous operation during overvoltages as high as 150 / 260V AC (3-Phase, 4-Wire, wye). Above this point, output is maintained utilizing battery reserves.
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features Automatic inverter bypass; Hot swappable batteries; Auto Probe Monitoring (requires WEBCARDLX); Zero transfer time; On-Line/Double-Conversion
Green Energy-Saving Features High efficiency economy mode operation; Schedulable daily hours of economy mode operation
WARRANTY & SUPPORT
Product Warranty Period (U.S. & Canada) 1-year limited warranty
3-Phase Warranty Statement Tripp Lite 3-Phase UPS Factory Warranty