SmartOnline 120V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, Network Card Options, USB, DB9 Serial

Sale!

$3,586.06

SmartOnline 120V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, Network Card Options, USB, DB9 Serial

Add to Wishlist
Add to Wishlist
Compare
SKU: SU3000RTXL3U Category:

Description

Specifications

OVERVIEW
UPC Code 037332117991
UPS Type On-Line
INPUT
Rated input current (Maximum Load) 24A
Nominal Input Voltage(s) Supported 120V AC
UPS Input Connection Type L5-30P
Input Circuit Breakers 40A
UPS Input Cord Length (ft.) 10
Recommended Electrical Service 30A 120V
Input Phase Single-Phase
OUTPUT
Output Volt Amp Capacity (VA) 3000
Output Capacity (kVA) 3
Output Watt Capacity (Watts) 2400
Output kW Capacity (kW) 2.4
Output Capacity Details OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)
Power Factor 0.8
Crest Factor 3:1
Frequency Compatibility 50 / 60 Hz
Frequency Compatibility Details Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start
Output Voltage Regulation (Line Mode) +/- 2%
Output Voltage Regulation (Economy Line Mode) +/- 10%
Output Voltage Regulation (Battery Mode) +/- 2%
Load Management Receptacles Two switchable four-outlet load banks, (bank 1 – four 5-15/20R, bank 2 – four 5-15R outlets)
Output Circuit Breakers 15A branch rated (x2) – each breaker protects 4 outlets, L5-30R is unbreakered
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Nominal Output Voltage(s) Supported 120V
Output Receptacles (4) 5-15R; (4) 5-15/20R; (1) L5-30R
Individually Controllable Load Banks Yes
BATTERY
Battery Type Valve Regulated Lead Acid (VRLA)
Full Load Runtime (min.) 5 min. (2400w)
Half Load Runtime (min.) 14 min. (1200w)
Expandable Battery Runtime Supports extended runtime with optional external battery packs
Expandable Runtime Yes
External Battery Pack Compatibility  BP72V15-2U  (limit 1);  BP72V28RT-3U  (multi-pack compatible);  BP72V18-2US  (multi-pack compatible)
DC System Voltage (VDC) 72
Battery Recharge Rate (Included Batteries) Less than 6 hours from 10% to 80% (typical, full load discharge)
Battery Access Front panel battery access door
Internal UPS Replacement Battery Cartridge  RBC96-3U  (quantity 1)
Battery Replacement Description Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage Regulation Description Online, double-conversion power conditioning
Overvoltage Correction 2% output voltage regulation during overvoltages to 150
Undervoltage Correction 2% output voltage regulation during undervoltages to 80
Severe Undervoltage Correction 2% output voltage regulation during undervoltages to 65 (under 70% load only)
USER INTERFACE, ALERTS & CONTROLS
Switches 2 switches control off/on power status and alarm-cancel/self-test operation
Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch
Audible Alarm Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
LED Indicators 14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 510
UPS AC Suppression Response Time Instantaneous
UPS Dataline Suppression 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet
EMI / RFI AC Noise Suppression Yes
PHYSICAL
Primary Form Factor Rackmount
Rack Height 3U
Cooling Method Fan
Included Mounting Accessory Description Includes 4 post rackmount installation accessories
Installation Form Factors Supported with Included Accessories 4 post 19 inch rackmount
Installation Form Factors Supported with Optional Accessories 2 post rackmount ( 2POSTRMKITHD ); Tower ( 2-9USTAND )
Minimum Required Rack Depth with External Battery Pack (cm) 81
Minimum Required Rack Depth with External Battery Pack (in.) 32
Minimum Required Rack Depth without External Battery Pack (cm) 79
Minimum Required Rack Depth without External Battery Pack (in.) 31
Primary UPS Depth (mm) 660
Primary UPS Height (mm) 132
Primary UPS Width (mm) 452
Shipping Dimensions (hwd / in.) 10.00 x 23.00 x 33.00
Shipping Weight (lbs.) 112.00
UPS Housing Material Steel
UPS Power Module Dimensions (hwd, in.) 5.2 x 17.8 x 26
UPS Power Module Weight (kg) 33.48
UPS Power Module Weight (lbs.) 73.8
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load) 1117
AC Economy Mode BTU / Hr. (Full Load) 523
Battery Mode BTU / Hr. (Full Load) 1224
AC Economy Mode Efficiency Rating (100% Load) 94%
COMMUNICATIONS
Network Management Cards SNMPWEBCARD;  TLNETCARD ;  WEBCARDLX ;  MODBUSCARD ;  RELAYIOCARD
Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications; Economy-mode setting option is available using PowerAlert software and DB9 Serial cable connection OR via select Network Management Card options
PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://www.tripplite.com/poweralert
Communications Cable USB and DB9 cabling included
WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
Network Management Card Description Network management card optional
Communications Interface Contact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)
LINE / BATTERY TRANSFER
Transfer Time No transfer time (0 ms.) in online, double-conversion mode
Low Voltage Transfer to Battery Power (Setpoint) 80V (100% load), 65V ( <70% load)
High Voltage Transfer to Battery Power (Setpoint) 150
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features Auto Probe Monitoring and Reboot (requires WEBCARDLX); Automatic inverter bypass; Expandable battery backup; Hot swappable batteries; On-Line/Double-Conversion; Remote management; Sine wave output; Surge/noise protection; Zero transfer time
Green Energy-Saving Features High efficiency economy mode operation; Individually controllable load banks; Schedulable daily hours of economy mode operation
STANDARDS & COMPLIANCE
Product Certifications CSA (Canada); NOM (Mexico); UL 1778
Product Compliance RoHS; FCC Part 15 Class A (USA)
WARRANTY & SUPPORT
Product Warranty Period (Worldwide) 2-year limited warranty
Connected Equipment Insurance (U.S., Canada & Puerto Rico) $250,000 Ultimate Lifetime Insurance

Additional information

Weight 50.8 kg
Dimensions 25.4 × 58.42 × 83.82 cm
Brand