SmartOnline 208/120V 10kVA 9kW Double-Conversion UPS, 10U, Extended Run, Network Card Slot, USB, DB9, Bypass Switch,NEMA

Sale!

KShs1,785,261.66

SmartOnline 208/120V 10kVA 9kW Double-Conversion UPS, 10U, Extended Run, Network Card Slot, USB, DB9, Bypass Switch,NEMA

Add to Wishlist
Add to Wishlist
Compare
SKU: SU10000RT3U2TF Category:

Description

Description Tripp Lite SU10000RT3U2TF 10,000VA / 10kVA / 9000 watt online, double-conversion UPS system offers complete power protection for critical network applications. This system delivers online, double-conversion UPS protection with zero transfer time, suitable for advanced networking applications. Fault-tolerant autobypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included detachable PDU with manual bypass switch enables hot-swappable replacement of entire UPS power module with no interruption to connected equipment. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations. Features Tripp Lite SU10000RT3U2TF 10kVA / 10,000VA / 9000 watt on-line, double-conversion UPS system in 10U total rack/tower configuration (3U UPS power module, 3U external battery pack and two 2U stepdown transformers) ● Detachable PDU with manual bypass switch enables hot-swappable UPS power module replacement with no interruption in output power to connected networking equipment ● ● Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions ● Hardwire input; 2 L6-30R, 4 L6-20R and 24 5-15/20R outlets ● Maximum installed rack depth of only 32.5 in. / 82.6cm Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise ● Double-conversion operation converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC with enhanced protection from harmonic distortion, fast electrical impulses and ● Highlights 10kVA / 10,000VA / 9000W online double-conversion UPS; 0.9 power factor; Extended runtime; Economy mode option ● 10U rack/tower configuration with hot-swappable power and battery modules; Maintenance bypass switch and two 5kVA transformer modules included ● USB, RS232 & EPO ports; Slot for network management card options; Front panel LCD monitoring and control screen ● Hardwire 208V 60Hz input (3 wire); NEMA L6-30R, L6-20R (208V) and 5-15/20R (120V) outlets ● Package Includes SU10000RT3UPM 3U UPS power module ● BP240V10RT3U external battery pack ● Two SU5000XFMRT2U step down transformers ● SUPDMB710 Detachable PDU with manual bypass switch ● Four post compatible rack rail kit (4 sets) ● ● Tower stands ● USB, DB9 and EPO Cabling ● User manual 1 / 7 Specifications other hard-to-solve power problems not addressed by other UPS types Maintains full-time sine wave output within 2% of 208/120V nominal at 60Hz during brownouts as low 100V and overvoltages as high as 300V ● Expandable runtime is supported with optional BP240V10RT3U; BP240V787C-1PH external battery packs ● Some external battery configurations require the use of Tripp Lite’s External Battery Configur (see manual) ● ● Intelligent battery management system with temperature-compensated charging extends battery life Highly efficient operation in optional economy mode significantly reduces BTU heat output and operating energy costs ● Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement ● USB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite’s PowerAlert software, available via FREE download from www.tripplite.com/poweralert ● HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X ● ● Slot for optional network management cards Compatible Tripp Lite UPS management card options TLNETCARD, WEBCARDLX, SNMPWEBCARD, MODBUSCARD and RELAYIOCARD support a wide variety of UPS control and monitoring capabilities ● Optional RELAYIOCARD supports six configurable hard contact closure outputs for custom event notification ● Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification (requires removal of USB interface module) ● ● Supports Emergency Power Off (EPO) via built-in interface ● Included rail kit supports 8U 19 inch rackmount installation in 4 post racks ● Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks Front panel LEDs and LCD readout with scroll controls and password option supports visual monitoring of all major UPS functions and advanced UPS settings for charge level, nominal voltage selection and other operational parameters ● ● LED / LCD display panel rotates for viewing in rackmount or tower configurations ● Network-grade AC surge and noise suppression Industrial mode option (factory preset) enables supports high current startup loads by momentarily switching to bypass mode in response to short duration overload conditions ● ● External battery packs are field replaceable and hot swappable OVERVIEW 2 / 7 UPC Code 037332127389 UPS Type On-Line OUTPUT Output Volt Amp Capacity (VA) 10000 Output kVA Capacity (kVA) 10 Output Watt Capacity (Watts) 9000 Output kW Capacity (kW) 9.0 Power Factor 0.9 Crest Factor 3:1 Nominal Voltage Details Voltage selection via front panel LCD interface; This configuration requires the Power Module be set to 208V output voltage; Included step-down transformers support 120V output Frequency Compatibility 60 Hz Frequency Compatibility Details Output frequency regulation +/- 0.05Hz (free running) Output Voltage Regulation (Line Mode) +/- 2% Output Voltage Regulation (Economy Line Mode) +/- 10% Output Voltage Regulation (Battery Mode) +/- 2% Output Circuit Breakers 20A double-pole (x2) protects 2 L6-20R outlets each, 30A double-pole (x2) protects 1 L6-30R outlets each, 20A single-pole (x8) protect 3 5-15/20R outlets each Output AC Waveform (AC Mode) Pure Sine wave Output AC Waveform (Battery Mode) Pure Sine wave Output Capacity Details Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less Nominal Output Voltage(s) Supported 120V; 208V Output Receptacles (24) 5-15/20R; (4) L6-20R; (2) L6-30R Individually Controllable Load Banks No INPUT Rated input current (Maximum Load) 54A (208V) Nominal Input Voltage(s) Supported 208V AC UPS Input Connection Type Hardwire UPS Input Connection Description 3 wire single phase input (L1, L2, G) Recommended Electrical Service 60A Input Phase Single-Phase 3 / 7 BATTERY Full Load Runtime (min.) 4.3 min. (9000w) Half Load Runtime (min.) 12.5 min. (4500w) Expandable Battery Runtime Supports extended runtime with optional external battery packs External Battery Pack Compatibility BP240V10RT3U; BP240V787C-1PH  DC System Voltage (VDC) 240 Battery Recharge Rate (Included Batteries) Less than 6 hours from 10% to 90% (typical, full load discharge) Battery Replacement Description Hot-swappable, user replaceable external battery packs Expandable Runtime Yes VOLTAGE REGULATION Voltage Regulation Description 2% output voltage regulation in standard online, double-conversion mode Overvoltage Correction Corrects overvoltages up to 300V Undervoltage Correction Corrects undervoltages as low as 100V USER INTERFACE, ALERTS & CONTROLS Front Panel LCD Display Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN, ITALIAN, SPANISH and PORTUGUESE (see manual) Switches 2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement Alarm Cancel Operation Alarm cancel switch Audible Alarm Unique audible alarms for all major UPS, environmental and power conditions (see manual) LED Indicators 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options SURGE / NOISE SUPPRESSION UPS AC Suppression Joule Rating 2565 UPS AC Suppression Response Time Instantaneous EMI / RFI AC Noise Suppression Yes ISOLATION Output Isolation Transformer 120V output is isolation transformer protected PHYSICAL Cooling Method Fan 4 / 7 Included Battery Pack Dimensions (hwd / in.) 5.25 x 17.5 x 25 Included Battery Pack Weight (kg) 71.99 Included Battery Pack Weight (lbs.) 158.7 Included Mounting Accessory Description 4 sets of adjustable 4 post rack rails included; Tower stands are included to support the entire 10U UPS bundle in upright tower configuration Installation Form Factors Supported with Included Accessories 4 post 19 inch rackmount Installation Form Factors Supported with Optional Accessories 2 post rackmount (2POSTRMKITHD) Maximum Device Depth (cm) 82.55 Maximum Device Depth (in.) 32.5 Maximum Device Depth (mm) 826 Minimum Required Rack Depth (cm) 95.25 Minimum Required Rack Depth (inches) 37.5 Optional Mounting Accessory Notes 4 sets of  2POSTRMKITHD  required for 2 post rackmount installation of separate power module, battery pack and set of two transformers Primary Form Factor Rackmount Primary UPS Depth (mm) 656 Primary UPS Height (mm) 131 Primary UPS Width (mm) 445 Rack Height 10U Shipping Dimensions (hwd / cm) 101.60 x 66.04 x 104.14 Shipping Dimensions (hwd / in.) 40.00 x 26.00 x 41.00 Shipping Weight (kg) 231.33 Shipping Weight (lbs.) 510.00 Stepdown Transformer Depth (mm) 528 Stepdown Transformer Dimensions (hwd / cm) 8.89 x 44.45 x 52.83 Stepdown Transformer Dimensions (hwd / in.) 3.5 x 17.5 x 20.8 Stepdown Transformer Height (mm) 89 Stepdown Transformer Weight (kg) 25.85 Stepdown Transformer Weight (lbs.) 57 Stepdown Transformer Width (mm) 445 UPS Dimensions Details Includes 3U UPS/power module, 3U battery pack, Two 2U SU5000XFMRT2U step down transformers plus SUPDMB710 PDU with bypass; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed UPS Housing Material Steel 5 / 7 UPS Power Module Dimensions (hwd, cm) 13.06 x 44.45 x 65.58 UPS Power Module Dimensions (hwd, in.) 5.14 x 17.5 x 25.82 UPS Power Module Weight (kg) 19.50 UPS Power Module Weight (lbs.) 43 ENVIRONMENTAL Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius Relative Humidity 0 to 95%, non-condensing AC Mode BTU / Hr. (Full Load) 3415 AC Economy Mode BTU / Hr. (Full Load) 1280 Battery Mode BTU / Hr. (Full Load) 4593 AC Mode Efficiency Rating (100% Load) 91% AC Economy Mode Efficiency Rating (100% Load) 96% Operating Elevation (ft.) 0-3000m (0 to 10,000 ft.) Audible Noise 60 dBA at front side 1 meter Operating Elevation (m) 0-3000 m COMMUNICATIONS Communications Interface USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface Network Management Cards SNMPWEBCARD; TLNETCARD; WEBCARDLX; MODBUSCARD; RELAYIOCARD  Network Monitoring Port Description Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert Communications Cable USB, DB9 serial and EPO cables included WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications LINE / BATTERY TRANSFER Transfer Time No transfer time (0 ms.) in online, double-conversion mode Transfer Time (Economy Mode) 8 ms. typical power failure response in optional economy mode Low Voltage Transfer to Battery Power (Setpoint) 100V High Voltage Transfer to Battery Power (Setpoint) 300V 6 / 7 © 2019 Tripp Lite. All rights reserved. All product and company names are trademarks or registered trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement by them. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Tripp Lite uses primary and third-party agencies to test its products for compliance with standards. See a list of Tripp Lite’s testing agencies: https://www.tripplite.com/products/product-certification-agencies SPECIAL FEATURES Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported Economy Mode Operation Optional economy mode enables high efficiency bypass operation with a maximum output voltage variation of +/- 10%. Double conversion mode is automatically restored as mains voltage varies beyond +/-10% with less than 1 millisecond transfer time between modes. High Availability UPS Features Automatic inverter bypass; Battery Independent Restart; Hot swappable UPS power module; Hot swappable batteries; Manual bypass switch Green Energy-Saving Features High efficiency economy mode operation; Schedulable daily hours of economy mode operation CERTIFICATIONS UPS Certifications Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI) UPS Certification Details IEC 61000-4-5 1995 B Surge Immunity WARRANTY Product Warranty Period (Worldwide) 2-year limited warranty Connected Equipment Insurance (U.S., Canada & Puerto Rico) $250,000 Ultimate Lifetime Insurance

Additional information

Weight 197.31 kg
Dimensions 101.6 × 66.04 × 104.14 cm
Brand