SmartOnline 208/240V 16kVA 14.4kW Double-Conversion UPS, N+1, 12U, Network Card Slot, USB, DB9 Serial, Bypass, L6-20R

Sale!

KShs2,736,399.38

SmartOnline 208/240V 16kVA 14.4kW Double-Conversion UPS, N+1, 12U, Network Card Slot, USB, DB9 Serial, Bypass, L6-20R

Add to Wishlist
Add to Wishlist
Compare
SKU: SU16KRT8 Category:

Description

Description
Tripp Lite SU16KRT8 16,000VA / 16kVA / 14,400 watt online, double-conversion UPS system offers complete
power protection for critical server, network and telecommunications equipment in a 12U rack/tower
configuration. This system delivers complete N+1 redundancy when used at loads up to 8kVA, and
non-redundant operation at loads between 8 and 16kVA. Fault-tolerant auto-bypass prevents unexpected
service interruptions during UPS overload or internal fault conditions. Included parallel PDU with manual bypass
switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined
operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS
ideal for advanced networking applications in data centers, computer rooms, network closets and rugged
industrial locations.
Features
Tripp Lite SU16KRT8 16kVA, 16,000VA / 14,400 watt on-line, double-conversion UPS system in 12U total rack/tower configuration
Unique configuration offers 16kVA non-redundant operation and automatic N+1 redundancy at load levels of 8kVA and under
Included Parallel PDU with manual bypass switch enables hot-swap replacement of power modules at any supported load level
Hardwire input; 8 L6-20R and 2 L6-30R outlets
Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominal
Supports 50/60Hz operation for worldwide frequency compatibility
Expandable runtime with optional external battery packs
Some external battery configurations require the use of Tripp Lite’s External Battery Configuration Software (see manual)
Battery independent restart
Intelligent battery management system with temperature-compensated charging extends battery life
Highly efficient economy mode option
Compatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX, SNMPWEBCARD, MODBUSCARD and RELAYIOCARD
Also compatible with RELAYIOMINI module (RELAYIOMINI requires removal of USB interface module)
Highlights
16kVA / 16,000VA / 14,400W
on-line double-conversion UPS,
0.9 power factor
200/208/220/230/240V 50/60Hz
output, 96% Efficient
Economy-mode option
Hot-swap power & battery
modules, N+1 fault tolerance at
loads up to 8kVA
USB, RS232, EPO ports, slot for
network management card
options
Front panel LEDs with detailed
LCD monitoring and control
screen
Expandable runtime with optional
external battery packs
Hardwire input (3 wire), L6-20R
and L6-30R outlets
Package Includes
Two SU8000RT3UPM UPS
power modules
Two BP240V10RT3U battery
packs
SUPDMB20K8 Parallel PDU with
Bypass switch
4-post rackmount installation rails
USB, DB9 & EPO Cabling
1 / 6
Applications utilizing the optional network communications card require two SNMPWEBCARD accessories (install one per included power module)
HID-compliant USB interface
USB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite’s PowerAlert software, available via FREE download from
www.tripplite.com/poweralert
Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (4 required)
Optional 2-9USTAND supports upright tower placement (2 required)
Supports Emergency Power Off (EPO) via built-in interface
Front panel LEDs and LCD readout with scroll controls
LED / LCD display panel rotates for viewing in rackmount or tower configurations
External battery packs are field replaceable and hot swappable
Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
Specifications
OUTPUT
Output Volt Amp Capacity (VA) 16000
Output kVA Capacity (kVA) 16
Output Watt Capacity (Watts) 14400
Output kW Capacity (kW) 14.4
Output Capacity Details
Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30
seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power;
Double conversion mode is automatically restored as load levels are reduced to 95% or less
Power Factor 0.9
Crest Factor 3:1
Nominal Output Voltage(s)
Supported 200V; 208V; 240V
Nominal Voltage Details Voltage selection via front panel LCD interface
Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
Frequency Compatibility Details Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to
50Hz or 50Hz to 60Hz (no de-rating)
Output Voltage Regulation (Line
Mode) +/- 2%
Output Voltage Regulation
(Economy Line Mode) +/- 10%
Output Voltage Regulation (Battery
Mode) +/- 2%
Output Receptacles (8) L6-20R; (2) L6-30R
Output Circuit Breakers 8 20A breakers protect one L6-20R outlet each, 2 30A breakers protect one L6-30R outlet each
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
2 / 6
INPUT
Rated input current (Maximum Load) 92A (200V), 88.4A (208V), 76.6A (240V)
Nominal Input Voltage(s) Supported 200V AC; 208V AC; 240V AC
UPS Input Connection Type Hardwire
UPS Input Connection Description 3 wire single phase input (L1, L2, G)
Recommended Electrical Service 100A @ 200V, 208V, or 240V (L1, L2, G)
Input Phase Single-Phase
BATTERY
Full Load Runtime (min.) 5.5 minutes (14,400 watts)
Half Load Runtime (min.) 13.5 minutes (7200 watts)
Expandable Battery Runtime Runtime is expandable with external battery packs
External Battery Pack Compatibility BP240V10RT3U; BP240V557C-1PH; BP240V787C-1PH; BP240V1037C-1PH; BP240V1407C-1PH
Expandable Runtime Description For best results, add external batteries in multiples of two so that both included 8kVA power modules have an equal
number and type of connected battery packs
DC System Voltage (VDC) 240
Battery Recharge Rate (Included
Batteries) Less than 6 hours from 10% to 90% (typical, full load discharge)
Battery Replacement Description Hot-swappable, user replaceable external battery packs
Expandable Runtime Yes
VOLTAGE REGULATION
Voltage Regulation Description 2% output voltage regulation in standard online, double-conversion mode
Overvoltage Correction Corrects overvoltages up to 300V
Undervoltage Correction Corrects undervoltages as low as 100V
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display
Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options;
LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN,
ITALIAN, SPANISH and PORTUGUESE (see manual)
Switches
2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and
execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module
replacement
Alarm Cancel Operation Alarm cancel switch
Audible Alarm Unique audible alarms for all major UPS, environmental and power conditions (see manual)
LED Indicators 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD
screen offers additional information and control options
SURGE / NOISE SUPPRESSION
3 / 6
UPS AC Suppression Response
Time Instantaneous
EMI / RFI AC Noise Suppression Yes
PHYSICAL
Included Mounting Accessory
Description 4 sets of adjustable 4 post rack rails included (one for each included 3U module)
Installation Form Factors Supported
with Optional Accessories 2 post rackmount(2POSTRMKITHD); Tower(2-9USTAND)
Optional Mounting Accessory Notes Qty 4 2POSTRMKITHD required for 2 post rackmount installation; Qty 2 2-9USTAND required for tower installation
Primary Form Factor Rackmount
UPS Power Module Dimensions
(hwd, in.) 5.14 x 17.5 x 25.82
UPS Power Module Dimensions
(hwd, cm) 13.06 x 44.45 x 65.58
Rack Height (U Spaces) 12
Maximum Device Depth (in.) 32.5
Minimum Required Rack Depth
(inches) 37.5
Maximum Device Depth (cm) 82.55
Minimum Required Rack Depth (cm) 95.25
UPS Power Module Weight (lbs.) 43
UPS Power Module Weight (kg) 19.50
UPS Dimensions Details
Includes 2 SU8000RT3UPM UPS/Power modules, 2 BP240V10RT3U Battery packs and SUPDMB20K8 parallel
bypass PDU; Listed weights and dimensions for UPS/Power module and Included battery pack each refer to a
single unit; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with parallel bypass
PDU installed
Included Battery Pack Dimensions
(hwd / in.) 5.25 x 17.5 x 25
Included Battery Pack Weight (lbs.) 158.7
Included Battery Pack Weight (kg) 71.99
UPS Shipping Dimensions (hwd / in.) 36 x 40.25 x 51
UPS Shipping Dimensions (hwd /
cm) 91.44 x 102.24 x 129.54
Shipping Weight (lbs.) 600
Shipping Weight (kg) 272.4
Cooling Method Fans
UPS Housing Material Steel
Maximum Device Depth (mm) 826
Minimum Required Rack Depth (mm) 952
4 / 6
Primary UPS Height (mm) 131
Primary UPS Width (mm) 444
Primary UPS Depth (mm) 656
Shipping Height (mm) 914
Shipping Width (mm) 1022
Shipping Depth (mm) 1295
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
Relative Humidity 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load) 5464
AC Economy Mode BTU / Hr. (Full
Load) 2047
Battery Mode BTU / Hr. (Full Load) 4864
AC Mode Efficiency Rating (100%
Load) 90%
AC Economy Mode Efficiency Rating
(100% Load) 96%
Operating Elevation (ft.) 0-3000m (0 to 10,000 ft.)
Audible Noise 60 dBA at front side 1 meter
Operating Elevation (m) 0-3000 m
COMMUNICATIONS
Communications Interface USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
Network Management Cards SNMPWEBCARD; TLNETCARD; WEBCARDLX; MODBUSCARD; RELAYIOCARD
Network Monitoring Port Description
Applications utilizing any supported network management card option, require the use of two network cards of the
same-model (install one card per included UPS power module); RELAYIOMINI installation requires removal of
panel containing USB ports on each included UPS power module
PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at
http://www.tripplite.com/poweralert
Communications Cable USB, DB9 serial and EPO cables included
WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER
Transfer Time No transfer time (0 ms.) in online, double-conversion mode
Transfer Time (Economy Mode) 8 milliseconds typical power failure response in optional economy mode
Low Voltage Transfer to Battery
Power (Setpoint) 100V
5 / 6
High Voltage Transfer to Battery
Power (Setpoint) 300V
SPECIAL FEATURES
Cold Start (Startup in Battery Mode
During a Power Failure) Cold-start operation supported
Economy Mode Operation
Optional economy mode enables high efficiency bypass operation with a maximum output voltage variation of
+/-10%. Double conversion mode is automatically restored as mains voltage varies beyond +/-10% with less than 1
millisecond transfer time between modes.
High Availability UPS Features Automatic inverter bypass; Hot swappable batteries; Hot swappable UPS power module; Manual bypass switch
Green Energy-Saving Features High efficiency economy mode operation; Support for daily startup and shutoff; Schedulable daily hours of economy
mode operation
CERTIFICATIONS
UPS Certifications Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI); ROHS (Restriction of
Hazardous Substances)
UPS Certification Details IEC 61000-4-5 1995 B Surge Immunity
WARRANTY
Product Warranty Period (Worldwide) 2-year limited warranty
Connected Equipment Insurance
(U.S., Canada & Puerto Rico) $250,000 Ultimate Lifetime Insurance

Additional information

Weight 272.6 kg
Dimensions 91.44 × 102.23 × 129.54 cm