Sale!
	
	
	
	
		
					
				
	
			
					
				
	
			
			
		
			
	
	
			Description
Specifications
OVERVIEW
| UPC Code | 037332198495 | 
| UPS Type | On-Line | 
INPUT
| Rated input current (Maximum Load) | 15A | 
| Nominal Input Voltage(s) Supported | 230V AC | 
| Nominal Input Voltage Description | 230V factory configuration | 
| UPS Input Connection Type | C20 inlet | 
| UPS Input Cord Length (ft.) | 5 | 
| Input Phase | Single-Phase | 
OUTPUT
| Output Volt Amp Capacity (VA) | 3000 | 
| Output Capacity (kVA) | 3 | 
| Output Watt Capacity (Watts) | 2500 | 
| Output kW Capacity (kW) | 2.5 | 
| Output Capacity Details | OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes, 150% for 30 seconds and >150% for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits of ±10% and ±5Hz) or SHUTDOWN (when bypass input voltage and frequency are OUTSIDE bypass limits of ±10% and ±5Hz) | 
| Power Factor | 0.83 | 
| Crest Factor | 3:1 | 
| Nominal Voltage Details | 230V default | 
| Frequency Compatibility | 50 / 60 Hz | 
| Frequency Compatibility Details | Output frequency matches input nominal on startup, defaults to 50 Hz on cold-start | 
| Output Voltage Regulation (Line Mode) | +/- 2% | 
| Output Voltage Regulation (Economy Line Mode) | +/-10% | 
| Output Voltage Regulation (Battery Mode) | +/- 2% | 
| Included Output Power Cables | Includes 2 C13 to C14 and 1 C19 to C20 power cables | 
| Load Management Receptacles | Two switchable 4 C13 outlet load banks | 
| Hot-Swap PDU options | PDUBHV20 (2U / 6 C13, 2 C19 outlets) | 
| Output AC Waveform (AC Mode) | Sine wave | 
| Output AC Waveform (Battery Mode) | Pure Sine wave | 
| Nominal Output Voltage(s) Supported | 230V | 
| Output Receptacles | (8) C13; (2) C19 | 
| Individually Controllable Load Banks | Yes | 
BATTERY
| Battery Type | Valve Regulated Lead Acid (VRLA) | 
| Full Load Runtime (min.) | 6 min. (2500w) | 
| Half Load Runtime (min.) | 15 min. (1250w) | 
| Expandable Battery Runtime | Supports extended runtime with optional external battery packs | 
| Expandable Runtime | Yes | 
| External Battery Pack Compatibility | BP72V15-2U (limit 1); BP72V28RT-3U (multi-pack compatible); BP72V18-2US (multi-pack compatible) | 
| DC System Voltage (VDC) | 72 | 
| Battery Recharge Rate (Included Batteries) | Less than 4.8 hours from 10% to 90% (typical, full load discharge) | 
| Battery Access | Front panel battery access door | 
| Internal UPS Replacement Battery Cartridge | See RBC selector | 
| Battery Replacement Description | Hot-swappable, replaceable batteries | 
VOLTAGE REGULATION
| Voltage Regulation Description | Online, double-conversion power conditioning | 
| Overvoltage Correction | 2% output voltage regulation during overvoltages to 288 | 
| Undervoltage Correction | 2% output voltage regulation during undervoltages to 160V (70-100% load) / 130V (30-70% load) / 100V (Under 30% load) | 
USER INTERFACE, ALERTS & CONTROLS
| Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation | 
| Alarm Cancel Operation | Power-fail alarm can be silenced using alarm-cancel switch | 
| Audible Alarm | Audible alarm indicates power failure, low battery, overload, replace battery and EPO operation | 
| LED Indicators | 14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats | 
SURGE / NOISE SUPPRESSION
| UPS AC Suppression Joule Rating | 570 | 
| EMI / RFI AC Noise Suppression | Yes | 
| AC Suppression Response Time | Instantaneous | 
PHYSICAL
| Primary Form Factor | Rackmount | 
| Rack Height | 2U | 
| Cooling Method | Fan | 
| Included Mounting Accessory Description | Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm) | 
| Installation Form Factors Supported with Included Accessories | 4 post 19 inch rackmount | 
| Installation Form Factors Supported with Optional Accessories | 2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM ) | 
| Minimum Required Rack Depth with External Battery Pack (cm) | 77 | 
| Minimum Required Rack Depth with External Battery Pack (in.) | 30.25 | 
| Minimum Required Rack Depth without External Battery Pack (cm) | 75 | 
| Minimum Required Rack Depth without External Battery Pack (in.) | 29.5 | 
| Optional Mounting Accessory Notes | Optional 2-9USTAND enables upright tower UPS placement; 2POSTRMKITWM enables wall-mount and 2-post rackmount installation; 4POSTRAILKITWM enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm); UPSHDEARKIT enables installation in 2 or 4-post racks using front vertical rails only, without rear support | 
| Primary UPS Depth (mm) | 616 | 
| Primary UPS Height (mm) | 88 | 
| Primary UPS Width (mm) | 438 | 
| Shipping Dimensions (hwd / in.) | 9.70 x 23.70 x 29.80 | 
| Shipping Weight (lbs.) | 84.70 | 
| UPS Housing Material | Steel | 
| UPS Power Module Dimensions (hwd, in.) | 3.46 x 17.24 x 24.25 | 
| UPS Power Module Weight (kg) | 31.17 | 
| UPS Power Module Weight (lbs.) | 68.72 | 
ENVIRONMENTAL
| Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius. | 
| Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius. | 
| Relative Humidity | 5 to 95%, non-condensing | 
| AC Mode BTU / Hr. (Full Load) | 742 | 
| AC Mode Efficiency Rating (100% Load) | 92% | 
COMMUNICATIONS
| Network Management Cards | WEBCARDLX | 
| Network Monitoring Port Description | Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications | 
| PowerAlert Software | For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://www.tripplite.com/poweralert | 
| Communications Cable | USB and DB9 cabling included | 
| WatchDog Compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications | 
| Network Management Card Description | Network management card optional | 
| Communications Interface | Contact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled) | 
LINE / BATTERY TRANSFER
| Transfer Time | No transfer time (0 ms.) in online, double-conversion mode | 
| Low Voltage Transfer to Battery Power (Setpoint) | 160V (70-100% load), 130V (30-70% load), 100V (less than 33% load) | 
| High Voltage Transfer to Battery Power (Setpoint) | 288V | 
FEATURES & SPECIFICATIONS
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported | 
| High Availability UPS Features | Auto Probe Monitoring and Reboot (requires WEBCARDLX); Automatic inverter bypass; Expandable battery backup; Hot swappable batteries; On-Line/Double-Conversion; Remote management; Sine wave output; Surge/noise protection; Zero transfer time | 
| Green Energy-Saving Features | High efficiency economy mode operation; Individually controllable load banks | 
| Grounding Lug | Grounding screw | 
STANDARDS & COMPLIANCE
| Product Certifications | RETIE (Colombia); CSA (Canada); UL 1778 | 
| Product Compliance | RoHS; CE (Europe); EAC (Belarus, Kazakhstan, Russia); REACH; FCC Part 15 Class A (USA) | 
WARRANTY & SUPPORT
| Product Warranty Period (Worldwide) | 2-year limited warranty | 
Additional information
| Weight | 38.41 kg | 
|---|---|
| Dimensions | 24.63 × 60.19 × 75.69 cm | 
| Brand | 