SmartOnline S3MX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS (No Internal Batteries)

Sale!

KShs1,424,268.69

SmartOnline S3MX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS (No Internal Batteries)

Add to Wishlist
Add to Wishlist
Compare
SKU: S3M30KX-NIB Category:

Description

Specifications

OVERVIEW
UPC Code 037332224118
UPS Type On-Line
INPUT
Rated input current (Maximum Load) 46.6A
Nominal Input Voltage(s) Supported 220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye
Nominal Input Voltage Description 3-Phase Wye, 4 wire plus ground (L1, L2, L3, N, G)
UPS Input Connection Type Hardwire
Input Circuit Breakers 63A (3 pole)
Input Phase 3-Phase
Power Factor (Input) .99PF (100% load)
THDi <3% (100% load)
OUTPUT
Output Volt Amp Capacity (VA) 30000
Output Capacity (kVA) 30
Output Watt Capacity (Watts) 27000
Output kW Capacity (kW) 27.00
Output Capacity Details Supports up to 100% load continuously in double conversion mode; Supports 100-110% load for 10 minutes, 110 to 130% load for 1 minute and greater than 130% for 1 second before switching to bypass mode; Inverter mode is automatically restored as load levels are reduced to less than 70%; Configuration options support up to 3 S3M30KX-NIB systems wired in parallel for increased capacity or fault-tolerant, redundant operation
Power Factor 0,9
Crest Factor 3:1
Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
Frequency Compatibility Details Automatic frequency selection
Output Voltage Regulation (Line Mode) +/- 1%
Output Voltage Regulation (Economy Line Mode) +/-11V of nominal
Output Voltage Regulation (Battery Mode) +/- 1%
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Nominal Output Voltage(s) Supported 220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye
Output Receptacles Hardwire
Individually Controllable Load Banks No
BATTERY
Expandable Battery Runtime Supports extended runtime with optional external battery packs
Expandable Runtime Yes
External Battery Pack Compatibility  BP480V09 ;  BP480V10 ;  BP480V10 -NIB;  BP480V100 ;  BP480V100 -NIB;  BP480V40 ;  BP480V40 -NIB;  BP480V65 ;  BP480V65 -NIB
DC System Voltage (VDC) +/- 240
Battery Recharge Rate (Included Batteries) 9 hours to 90% (Internal batteries)
VOLTAGE REGULATION
Voltage Regulation Description Online, double-conversion power conditioning maintains output within 1% of the selected nominal voltage in online mode
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display LCD DISPLAY: offers a variety of graphical, text and numeric information to indicate a wide range of UPS operation and fault / warning conditions, including current operating mode, alarm status, load level, battery charge, input / output voltage & frequency, estimated runtime and more (see user manual for a detailed listing)
Switches ON / ENTER BUTTON: turns the UPS on and confirms a selection from the settings menu; OFF / ESC BUTTON: turns off the UPS and returns to the previous item in the settings menu; TEST / UP BUTTON: initiates UPS self-test operation and advances to the next item in the settings menu; MUTE / DOWN BUTTON: silences the audible alarm and advances to the previous item in the settings menu; Press TEST/UP & MUTE/DOWN buttons simultaneously for 1 second to enter or exit the settings menu (See user manual for detailed information)
Audible Alarm Alarms warn users of a variety of operational conditions: BYPASS MODE (beeps every 2 seconds), BATTERY MODE (beeps every 4 seconds), FAULT MODE (beeps continuously), OVERLOAD (beeps twice per second), OTHER WARNINGS (beeps once per second), FAULT (beeps continuously); All alarms can be silenced, except OVERLOAD & OTHER WARNINGS conditions
LED Indicators 4 LEDs report BYPASS / LINE / BATTERY / FAULT modes

Additional information

Weight 99.79 kg
Dimensions 120.49 × 42.29 × 91.99 cm
Brand