SmartOnline S3MX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Parallel for Capacity and Redundancy, Single & Dual AC Input, No Internal Batteries

Sale!

KShs1,668,067.57

SmartOnline S3MX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Parallel for Capacity and Redundancy, Single & Dual AC Input, No Internal Batteries

Add to Wishlist
Add to Wishlist
Compare
SKU: S3M30KXD-NIB Category:

Description

Features Battery Backup Option and VFI Operation Protect Critical LoadsThe SmartOnline® S3M30KXD-NIB IGBT UPS supports the continuous availability of your most important loads through all power conditions, providing a compact backup power platform that’s easy to manage and inexpensive to operate. Sophisticated voltage and frequency independent (VFI) operation and advanced IGBT rectifier technology with DSP control deliver reliable output power quality. Providing up to 30kVA of clean, continuous power, this 3-phase UPS system is perfect for critical applications in IT, communications, corporate, commercial, retail, financial, security, transportation, emergency and edge infrastructure environments. Best-in-Class Footprint for Easy Integration into Your Network ApplicationThis on-line doubleconversion UPS system has a very small footprint of just 0.24 square meters. It requires less valuable space in your facility, and you can install the UPS system in spaces that would previously have required expensive retrofitting. Efficient Operation and Design Reduces Cost of OwnershipThis UPS benefits from highly efficient transformer-free double-conversion technology that delivers operating cost savings. It achieves 94% efficiency in double-conversion mode and up to 98% in ECO mode, reducing your power and cooling costs. A low THDi (<3%) improves generator compatibility. A low THDv (2%) and active power factor correction improve output performance. The hardware and firmware platform design reduces the number of unique boards, improving mean time to repair (MTTR) and resulting in reduced downtime. Built-in static and maintenance bypass transfer UPS load to utility power during faults, overloads and maintenance, which also avoids costly system downtime. External Batteries Supply Reliable Backup with Expandable Runtime OptionsThe S3M30KXD-NIB online double-conversion UPS uses external scalable battery cabinets (sold separately) to provide backup support in case of a power failure. For instance, the Tripp Lite BP480V65 provides up to 41 minutes of extended runtime at full load, and the BP480V40 provides up to 22 minutes. The UPS system automatically restarts after a lengthy power outage. Highlights Best-in-class footprint and power density minimize space requirements for up to 30kVA ● Intuitive LCD interface offers key performance, configuration and diagnostics info ● High efficiency (94% on-line, 98% ECO mode) helps reduce operating costs ● Add optional WEBCARDLX with latest version of PADM20 for enhanced remote management ● Parallel for capacity and redundancy up to 3 units ● Single and dual AC input capability ● Applications Fit 30kVA UPS in best-in-class footprint to save space for revenue-generating equipment ● Back up critical IT equipment and data in network, telecom, financial and commercial applications ● Maintain server-room operations during all power conditions, including short blackouts ● Package Includes S3M30KXD-NIB SmartOnline S3MX Series 3-Phase 380/400/415V 30kVA 27kW OnLine Double-Conversion UPS (No Internal Batteries) ● ● RS-232 cable ● Paralleling cable kit ● Owner’s manual 1 / 5 Specifications Intuitive LCD Interface Delivers Important Performance Information at a GlanceThe interactive frontpanel LCD interface displays critical operating conditions and diagnostic data, including operating mode, input/output voltage, load, battery voltage, backup runtime and fault conditions. Four LEDs provide information about line, bypass, battery and fault status. Network Management Card Offers Remote Monitoring and ControlThe optional WEBCARDLX (sold separately) with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and Tripp Lite’s PowerAlert Element Manager (PAEM) software form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations. Parallel Capability Provides Additional CapacityConnect up to three S3M30KXD-NIB units in parallel using separate/shared battery cabinets for increased capacity. 2-Year Warranty Provides Peace of MindThe S3M30KXD-NIB is backed by a 2-year limited warranty, ensuring reliability and performance. OVERVIEW UPC Code 037332239747 UPS Type On-Line INPUT Rated input current (Maximum Load) 46.6A Nominal Input Voltage(s) Supported 220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye Nominal Input Voltage Description 3-Phase Wye, 4 wire plus ground (L1, L2, L3, N, G) UPS Input Connection Type Hardwire Input Circuit Breakers 63A (3 pole) Input Phase 3-Phase Power Factor (Input) .99PF (100% load) THDi <3% (100% load) OUTPUT Output Volt Amp Capacity (VA) 30000 Output Capacity (kVA) 30 Output Watt Capacity (Watts) 27000 Output kW Capacity (kW) 27.00 Output Capacity Details Supports up to 100% load continuously in double conversion mode; Supports 100-110% load for 10 minutes, 110 to 130% load for 1 minute and greater than 130% for 1 second before switching to bypass mode; Inverter mode is automatically restored as load levels are reduced to less than 70%; Configuration options support up to 3 S3M30KX-NIB systems wired in parallel for increased capacity or fault-tolerant, redundant operation Power Factor 0.9 2 / 5 Crest Factor 3:1 Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion Frequency Compatibility Details Automatic frequency selection Output Voltage Regulation (Line Mode) +/- 1% Output Voltage Regulation (Economy Line Mode) +/-11V of nominal Output Voltage Regulation (Battery Mode) +/- 1% Output AC Waveform (AC Mode) Pure Sine wave Output AC Waveform (Battery Mode) Pure Sine wave Nominal Output Voltage(s) Supported 220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye Output Receptacles Hardwire Individually Controllable Load Banks No BATTERY Expandable Battery Runtime Supports extended runtime with optional external battery packs Expandable Runtime Yes External Battery Pack Compatibility  BP480V09 ;  BP480V10 ;  BP480V10 -NIB;  BP480V100 ;  BP480V100 -NIB;  BP480V40 ;  BP480V40 -NIB;  BP480V65 ;  BP480V65 -NIB DC System Voltage (VDC) +/- 240 Battery Recharge Rate (Included Batteries) 9 hours to 90% (Internal batteries) VOLTAGE REGULATION Voltage Regulation Description Online, double-conversion power conditioning maintains output within 1% of the selected nominal voltage in online mode USER INTERFACE, ALERTS & CONTROLS Front Panel LCD Display LCD DISPLAY: offers a variety of graphical, text and numeric information to indicate a wide range of UPS operation and fault / warning conditions, including current operating mode, alarm status, load level, battery charge, input / output voltage & frequency, estimated runtime and more (see user manual for a detailed listing) Switches ON / ENTER BUTTON: turns the UPS on and confirms a selection from the settings menu; OFF / ESC BUTTON: turns off the UPS and returns to the previous item in the settings menu; TEST / UP BUTTON: initiates UPS self-test operation and advances to the next item in the settings menu; MUTE / DOWN BUTTON: silences the audible alarm and advances to the previous item in the settings menu; Press TEST/UP & MUTE/DOWN buttons simultaneously for 1 second to enter or exit the settings menu (See user manual for detailed information) 3 / 5 Audible Alarm Alarms warn users of a variety of operational conditions: BYPASS MODE (beeps every 2 seconds), BATTERY MODE (beeps every 4 seconds), FAULT MODE (beeps continuously), OVERLOAD (beeps twice per second), OTHER WARNINGS (beeps once per second), FAULT (beeps continuously); All alarms can be silenced, except OVERLOAD & OTHER WARNINGS conditions LED Indicators 4 LEDs report BYPASS / LINE / BATTERY / FAULT modes PHYSICAL Primary Form Factor Tower Cooling Method Fans Installation Form Factors Supported with Included Accessories Tower Primary UPS Depth (mm) 815 Primary UPS Height (mm) 1,000 Primary UPS Width (mm) 300 Shipping Dimensions (hwd / in.) 47.44 x 16.90 x 36.22 Shipping Weight (kg) 99.79 UPS Housing Material Steel UPS Power Module Dimensions (Height x Width x Depth, mm) 1000 x 300 x 815 UPS Power Module Dimensions (hwd, in.) 39.37 x 11.81 x 32.08 UPS Power Module Weight (kg) 63.50 UPS Power Module Weight (lbs.) 140 ENVIRONMENTAL Operating Temperature Range 0 to +40C (32-104F) Storage Temperature Range 0 to +35C (32 to 95F) with battery; -15 to 60C (5 to +140F) without battery Relative Humidity 5 to 95%, non-condensing Operating Elevation (ft.) < 3280ft (Capacity de-rates by 1% for every 328ft over 3280ft ) Audible Noise <60dBA at 1meter Operating Elevation (m) < 1000m (Capacity de-rates by 1% for every 100m over 1000m) COMMUNICATIONS Network Management Cards  WEBCARDLX ;  MODBUSCARDSV ;  RELAYCARDSV  Network Monitoring Port Description Card accessory slot supports network management interface or programmable I/O relay card options Communications Cable DB9/RS-232 cable included Communications Interface DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface 4 / 5 © 2021 Tripp Lite. All rights reserved. All product and company names are trademarks or registered trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement by them. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Tripp Lite uses primary and third-party agencies to test its products for compliance with standards. See a list of Tripp Lite’s testing agencies: https://www.tripplite.com/products/product-certification-agencies LINE / BATTERY TRANSFER Transfer Time Zero transfer time Online to Battery, Inverter to Bypass 0ms (Synchronous), and Inverter to ECO mode < 10ms. Low Voltage Transfer to Battery Power (Setpoint) 120V(Ph-N), 208V (Ph-Ph) @ 50% load / 176V (Ph-N), 305V (Ph-Ph) @ 100% load. High Voltage Transfer to Battery Power (Setpoint) 276 (Ph-N), 478V (Ph-Ph) @ 50% or 100% load. FEATURES & SPECIFICATIONS Grounding Lug Yes Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported High Availability UPS Features Automatic inverter bypass; Manual bypass switch; Auto Probe Monitoring (requires WEBCARDLX); Zero transfer time; On-Line/Double-Conversion Green Energy-Saving Features High efficiency economy mode operation STANDARDS & COMPLIANCE UPS Certifications CE Certification Details IEC/EN 62040-1:2008+A1 (Safety); IEC/EN 62040-2:2006 (Category C3) WARRANTY Product Warranty Period (U.S. & Canada) 2-year limited warranty Product Warranty Period (International) 2-year limited warranty Product Warranty Period (Mexico) 2-year limited warranty Product Warranty Period (Puerto Rico) 2-year limited warranty 3-Phase Warranty Statement Tripp Lite 3-Phase UPS Factory Warranty

Additional information

Weight 99.79 kg
Dimensions 120.49 × 42.92 × 91.99 cm
Brand