SmartOnline SV Series 80kVA Large-Frame Modular Scalable 3-Phase On-Line Double-Conversion 208/120V 50/60 Hz UPS System

Sale!

KShs10,709,870.60

SmartOnline SV Series 80kVA Large-Frame Modular Scalable 3-Phase On-Line Double-Conversion 208/120V 50/60 Hz UPS System

Add to Wishlist
Add to Wishlist
Compare
SKU: SV80KL Category:

Description

Specifications

OVERVIEW
UPC Code 037332278777
UPS Type On-Line
INPUT
Rated input current (Maximum Load) SV100KL 80kVA Configuration: 240A; Maximum 140kVA Large Chassis Configuration: 420A; 330A maximum inrush current
Nominal Input Voltage(s) Supported 120/208V 3-PH Wye; 127/220V 3-PH Wye
Nominal Input Voltage Description Set of two hardwire input connections enables 3-Phase Wye, 4 wire (3P, N, G) inputs from two separate power sources
UPS Input Connection Type Hardwire
Input Circuit Breakers MAIN and ALTERNATE AC inputs are each protected by 630A 3 pole magnetic breakers
Input Phase 3-Phase
Input Frequency 40 to 70Hz (online mode); 50/60Hz Auto-selectable
Power Factor (Input) 0.99 (full load)
THDi Less than 3% (full linear load)
OUTPUT
Output Volt Amp Capacity (VA) 80000
Output Capacity (kVA) 80
Output Watt Capacity (Watts) 72000
Output kW Capacity (kW) 72
Output Capacity Details OVERLOAD CAPABILITY: Supports 105-110% load for 1 hour, 111-125% load for 10 minutes, 126-150% for 1 minute and Over 150% for 200ms before switching to Bypass; Online operation resumes when load is reduced to 100% or less
Power Factor 0.9
Crest Factor 3:1
Nominal Voltage Details Output THD full resistive load: <1.5%; Output THD non-linear load: <4%; Max DC offset: ±50mV; Max Phase angle deviation: 2°; Max Voltage unbalance deviation: 1%; Output short-circuit protection included
Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
Frequency Compatibility Details Auto-selectable, user adjustable
Output Receptacle Details Output wiring: 3P, N, E
Output Circuit Breakers 630A 3 pole magnetic breaker
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Nominal Output Voltage(s) Supported 120/208V 3-PH Wye; 127/220V 3-PH Wye
Output Receptacles Hardwire
Output Voltage Regulation ONLINE, FREQUENCY CONVERSION, BATTERY MODE: 208/120, 220/127 ±1% typical (balanced load); ±2% typical (unbalanced load); ECONOMY MODE: 208/120, 220/127 ±15V; BYPASS MODE: +15% (default, adjustable to +10%, +15% or +20%), -20% (default, adjustable to -10%, -20%, -30%)
Output Frequency Regulation ONLINE MODE: Output frequency is ±0.05Hz of input frequency when input is within ±4Hz* of the configured 50/60Hz output setting; Output frequency is ±0.05Hz the configured 50/60Hz output setting when input is outside ±4Hz* of the configured 50/60Hz output setting; BATTERY MODE: Output frequency is ±0.1Hz of the configured 50/60Hz output setting; FREQUENCY CONVERTER MODE: Output frequency is ±0.1Hz of the configured 50/60Hz output setting; ECONOMY MODE: Output frequency equals input frequency up to ±4Hz* of the configured 50/60Hz output setting (UPS switches to Online mode if frequency goes outside of this range); BYPASS MODE: Output frequency equals input frequency up to ±4Hz* of the configured 50/60Hz output setting (switches to STANDBY mode if frequency goes outside of this range). *The TRACKING RANGE is factory set to ±4Hz and is user adjustable to ±1Hz, ±2Hz or ±4Hz; The selected TRACKING RANGE setting controls frequency output tolerances as described above in Online, Economy and Bypass modes
Output Amp Capacity Output Amp Capacity 222A (208/120V); 210A (220/127V)
Individually Controllable Load Banks No
Modular Upgrade Options Includes 4 SV20PM 20kVA power modules. Up to 4 additional SV20PM 20kVA power modules can be added for additional capacity or N+1 availability; Add 1 SV20PM for 100kVA capacity (or 80kVA with N+1 redundancy); Add 2 SV20PM for 120kVA capacity (or 100kVA with N+1 redundancy); Add 3 SV20PM for 140kVA capacity (or 120kVA with N+1 redundancy); Add 4 SV20PM for 140kVA total capacity with N+1 redundancy
BATTERY
Full Load Runtime (min.) Batteries sold separate; Runtime is dependent on battery pack quantity and load level
Expandable Battery Runtime Supports extended runtime with optional external battery packs; 400A 3 pole 250VDC breaker recommended for external battery
Expandable Runtime Yes
Expandable Runtime Description External battery pack wiring is contractor supplied
External Battery Pack Compatibility  BP240V370 ;  BP240V370NB ;  EBP240V2502 ;  EBP240V2502NB ;  EBP240V3501 ;  EBP240V3501NB ;  EBP240V3502 ;  EBP240V3502NB ;  EBP240V5001 ;  EBP240V5001NB ;  EBP240V5002 ;  EBP240V5002NB ;  EBP240V6002 ;  EBP240V6002NB ;  EBP240V6003 ;  EBP240V6003NB
DC System Voltage (VDC) ±120VDC
Battery Recharge Rate (Included Batteries) User selectable charging current of 1A to 32A (2A factory setting); Recharge rate is dependent on number of external battery packs connected and the selected charge current setting
Battery Replacement Description Hot-swappable, replaceable batteries
VOLTAGE REGULATION
Voltage Regulation Description Online, double-conversion power conditioning
Overvoltage Correction Maintains continuous output in online mode, without using battery power, during overvoltages to 253V (Ph-Ph), reducing output to within 1% of selected 208/120V, 220/127V nominal output voltage
Undervoltage Correction Maintains continuous output in online mode, without using battery power, during brownout/undervoltage conditions to 156V (Ph-Ph) at full load and to 121V (Ph-Ph) at 70% output load or less, increasing output to within 1% of selected 208/120V or 220/127V nominal output voltage
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display 145mm front panel LCD display with directional scroll and select buttons offers complete operating status display, plus setting and selection options for all UPS functions
Switches Front panel buttons include ESC (menu escape), UP/LEFT (menu up / left), DOWN/RIGHT (menu down / right), ENTER (confirm selection), HOME (return to home screen) and POWER (on/off power control); Also includes Manual Bypass switch
Alarm Cancel Operation Audible alarms can be muted using on-screen prompts
Audible Alarm Unique audible alarms for POWER ON / POWER OFF (alarm sounds for 2 seconds), BATTERY MODE (alarm sounds every 2 seconds), LOW BATTERY (alarm sounds every 0.5 seconds), UPS ALARM (alarm sounds every 1 second), UPS FAULT (continuous alarm)
LED Indicators Front panel LED indicators represent INPUT (green), BYPASS (amber), INVERTER (green), BATTERY (red) and ALARM (red)
SURGE / NOISE SUPPRESSION
EMI / RFI AC Noise Suppression Yes
AC Suppression Joule Rating 2496
AC Suppression Joule Rating Details 2496 joules (Ph-Ph), 2496 joules (Ph-N), 1872 joules (N-E)
AC Suppression Response Time Instantaneous
PHYSICAL
Primary Form Factor Tower
Cooling Method Fans
Installation Form Factors Supported with Included Accessories Tower
Primary UPS Depth (mm) 1,100
Primary UPS Height (mm) 2,010
Primary UPS Width (mm) 600
Shipping Dimensions (hwd / in.) 75.00 x 29.00 x 48.00
Shipping Weight (lbs.) 1055.00
UPS Housing Material Steel
UPS Power Module Dimensions (hwd, in.) 79.13 x 23.62 x 43.3
UPS Power Module Weight (kg) 411.00
UPS Power Module Weight (lbs.) 906.1
ENVIRONMENTAL
Operating Temperature Range 0° to +40°C (+32° to +104°F); De-rates to 90% capacity at 35°C / 95°F and 80% capacity at 40°C / 104°F
Storage Temperature Range -15° to +60°C (+5° to +140°F)
Relative Humidity 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load) 23499
AC Economy Mode BTU / Hr. (Full Load) 1881
AC Economy Mode Efficiency Rating (100% Load) 99%
Audible Noise Less than 65 dBA front-side, 1m
Operating Elevation (m) Up to 1000m (At elevations over 1000m, output de-rates by 1% per 100m)
COMMUNICATIONS
Network Management Cards  WEBCARDLX ;  MODBUSCARDSV ;  RELAYCARDSV
Network Monitoring Port Description Includes pre-installed Tripp Lite WEBCARDLX network interface
PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://www.tripplite.com/poweralert
Communications Cable DB9 cabling included
SNMP Compatibility SNMP Compatibility Includes pre-installed  WEBCARDLX  network interface card
Communications Interface DB9 Serial; EPO (emergency power off); Pre-installed network card; Slot for SNMP/Web interface
LINE / BATTERY TRANSFER
Transfer Time No transfer time (0 ms.) in online, double-conversion mode; Less than 20 ms. transfer time in economy mode
Low Voltage Transfer to Battery Power (Setpoint) Maintains continuous operation without using battery power during brownout/undervoltage conditions to to 156V (Ph-Ph) Full load or 121V (Ph-Ph) 70% load or less; Below the low transfer voltage point, output is maintained utilizing reserve battery power
High Voltage Transfer to Battery Power (Setpoint) Maintains continuous operation without using battery power during overvoltages to 253V (Ph-Ph), reducing output within 1% of nominal; Above this point, output is maintained utilizing reserve battery power
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features Automatic inverter bypass; Hot swappable batteries; Hot swappable UPS power module; Auto Probe Monitoring (included); Zero transfer time; On-Line/Double-Conversion
Green Energy-Saving Features Greater than 95% efficiency – GREEN UPS; High efficiency economy mode operation; Schedulable daily hours of economy mode operation
IP68 Rated No
STANDARDS & COMPLIANCE
Product Certifications CSA (Canada); NOM (Mexico); UL 1778
Product Compliance RoHS; FCC Part 15 Class A (USA)
WARRANTY & SUPPORT
Product Warranty Period (U.S. & Canada) 1-year limited warranty
3-Phase Warranty Statement Tripp Lite 3-Phase UPS Factory Warranty