SmartOnline SVTX Series 3-Phase 380/400/415V 10kVA 9kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Sale!

KShs1,242,165.47

SmartOnline SVTX Series 3-Phase 380/400/415V 10kVA 9kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Add to Wishlist
Add to Wishlist
Compare
SKU: SVT10KX Category:

Description

Specifications

OVERVIEW
UPC Code 037332192455
UPS Type On-Line
INPUT
Rated input current (Maximum Load) 17.4A
Nominal Input Voltage(s) Supported 220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye
Nominal Input Voltage Description 3-Phase Wye, 4 wire plus ground (L1, L2, L3, N, G)
UPS Input Connection Type Hardwire
Input Phase 3-Phase
Power Factor (Input) .99PF (100% load)
THDi <6%
OUTPUT
Output Volt Amp Capacity (VA) 10000
Output Capacity (kVA) 10
Output Watt Capacity (Watts) 9000
Output kW Capacity (kW) 9
Output Capacity Details Supports up to 100% load continuously in double conversion mode; Supports 100-110% load for 10 minutes, 110 to 130% load for 1 minute and greater than 130% for 1 second before switching to bypass mode; Inverter mode is automatically restored as load levels are reduced to 70% or less
Power Factor 0.9
Crest Factor 3:1
Frequency Compatibility 50 / 60 Hz
Frequency Compatibility Details Automatic frequency selection
Output Voltage Regulation (Line Mode) +/- 1%
Output Voltage Regulation (Economy Line Mode) +/-11V of selected nominal output voltage (220V: 209-231V; 230V: 219-241; 240V: 229-251V)
Output Voltage Regulation (Battery Mode) +/- 1%
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Nominal Output Voltage(s) Supported 220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye
Output Receptacles Hardwire
Individually Controllable Load Banks No
BATTERY
Full Load Runtime (min.) 3.8 min (9kW)
Half Load Runtime (min.) 10.5 min. (4.5kW)
Expandable Battery Runtime Supports extended runtime optional external battery packs
Expandable Runtime Yes
External Battery Pack Compatibility  BP240V135
DC System Voltage (VDC) 240
Battery Recharge Rate (Included Batteries) 4 hours to 90% (Internal batteries)
VOLTAGE REGULATION
Voltage Regulation Description Online, double-conversion power conditioning maintains output within 1% of the selected nominal voltage in online mode
Overvoltage Correction Corrects overvoltage conditions to 520V (50% load) and 478V (100% load)
Undervoltage Correction Corrects brownout conditions to 110V (50% load) / 305V (100% load)
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display LCD DISPLAY: offers a variety of graphical, text and numeric information to indicate a wide range of UPS operation and fault / warning conditions, including current operating mode, alarm status, load level, battery charge, input / output voltage & frequency, estimated runtime and more (see user manual for a detailed listing)
Switches ON / ENTER BUTTON: turns the UPS on and confirms a selection from the settings menu; OFF / ESC BUTTON: turns off the UPS and returns to the previous item in the settings menu; TEST / UP BUTTON: initiates UPS self-test operation and advances to the next item in the settings menu; MUTE / DOWN BUTTON: silences the audible alarm and advances to the previous item in the settings menu; Press TEST/UP & MUTE/DOWN buttons simultaneously for 1 second to enter or exit the settings menu (See user manual for detailed information)
Audible Alarm Alarms warn users of a variety of operational conditions: BYPASS MODE (beeps every 2 seconds), BATTERY MODE (beeps every 4 seconds), FAULT MODE (beeps continuously), OVERLOAD (beeps twice per second), OTHER WARNINGS (beeps once per second), FAULT (beeps continuously); All alarms can be silenced, except OVERLOAD & OTHER WARNINGS conditions
LED Indicators 4 LEDs report BYPASS / LINE / BATTERY / FAULT modes
PHYSICAL
Primary Form Factor Tower
Cooling Method Fans
Installation Form Factors Supported with Included Accessories Tower
Primary UPS Depth (mm) 813
Primary UPS Height (mm) 861
Primary UPS Width (mm) 249
Shipping Dimensions (hwd / in.) 41.74 x 14.96 x 36.22
Shipping Weight (lbs.) 295.00
UPS Housing Material Steel
UPS Power Module Dimensions (Height x Width x Depth, mm) 862 x 250 x 813
UPS Power Module Dimensions (hwd, in.) 33.9 x 9.8 x 32
UPS Power Module Weight (kg) 117.93
UPS Power Module Weight (lbs.) 260
ENVIRONMENTAL
Operating Temperature Range 0 to +40C (32-104F)
Storage Temperature Range 0 to +35C (32 to 95F) with battery; -15 to 60C (5 to +140F) without battery
Relative Humidity 5 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load) 3415
Operating Elevation (ft.) < 3000ft (Capacity de-rates by 1% for every 330ft over 3000)
Audible Noise <65dBA front side 1M
Operating Elevation (m) < 1000m (Capacity de-rates by 1% for every 100m over 1000)
COMMUNICATIONS
Network Management Cards  WEBCARDLX ;  MODBUSCARDSV ;  RELAYCARDSV
Network Monitoring Port Description Card accessory slot also supports network interface and relay card options
Communications Cable DB9 cabling included
Communications Interface DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
LINE / BATTERY TRANSFER
Transfer Time Zero transfer time in ONLINE MODE (0ms); ECONOMY MODE: 7ms from AC to Battery mode / 0.6ms from Battery to AC mode
Low Voltage Transfer to Battery Power (Setpoint) 110V (50% load) / 305V (100% load)
High Voltage Transfer to Battery Power (Setpoint) 520V (50% load) / 478V (100% load)
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features Automatic inverter bypass; Manual bypass switch; Auto Probe Monitoring (requires WEBCARDLX); Zero transfer time; On-Line/Double-Conversion
Green Energy-Saving Features High efficiency economy mode operation
Grounding Lug Yes
IP68 Rated No
STANDARDS & COMPLIANCE
Product Certifications IEC/EN 62040
Product Compliance RoHS; CE (Europe)
WARRANTY & SUPPORT