SmartOnline SVX Series 60kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double-Conversion Medium-Frame UPS System, 3 Battery Modules
Description
Specifications OUTPUT Output Volt Amp Capacity (VA) Output kVA Capacity (kVA) Output Watt Capacity (Watts) Output kW Capacity (kW) Output Capacity Details 60000 60 60000 60 OVERLOAD CAPABILITY: Supports 105-110% load for 1 hour, 111-125% load for 10 minutes, 126-150% for 1 minute and Over 150% for 200ms before switching to Bypass; Online operation resumes when load is reduced to 100% or less Power Factor 1.0 2 / 6Crest Factor3:1 Nominal Output Voltage(s) Supported220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye Nominal Voltage DetailsOutput THD full resistive load: <1.5%; Output THD non-linear load: <4%; Max DC offset: ±50mV; Max Phase angle deviation: 2°; Max Voltage unbalance deviation: 1%; Output short-circuit protection included Frequency Compatibility50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion Frequency Compatibility DetailsAuto-selectable, user adjustable Output ReceptaclesHardwire Output Receptacle DetailsOutput wiring: 3P, N, E Output Circuit Breakers400A 3 pole magnetic breaker Output AC Waveform (AC Mode)Pure Sine wave Output AC Waveform (Battery Mode)Pure Sine wave Output Voltage RegulationONLINE, FREQUENCY CONVERSION, BATTERY MODE: 220/230/240V ±1% typical (balanced load); ±2% typical (unbalanced load); ECONOMY MODE: 220/230/240V ±15V; BYPASS MODE: +15% (default, adjustable to +10%, +15% or +20%), -20% (default, adjustable to -10%, -20%, -30%) Output Frequency RegulationONLINE MODE: Output frequency is ±0.05Hz of input frequency when input is within ±4Hz* of the configured 50/60Hz output setting; Output frequency is ±0.05Hz the configured 50/60Hz output setting when input is outside ±4Hz* of the configured 50/60Hz output setting; BATTERY MODE: Output frequency is ±0.1Hz of the configured 50/60Hz output setting; FREQUENCY CONVERTER MODE: Output frequency is ±0.1Hz of the configured 50/60Hz output setting; ECONOMY MODE: Output frequency equals input frequency up to ±4Hz* of the configured 50/60Hz output setting (UPS switches to Online mode if frequency goes outside of this range); BYPASS MODE: Output frequency equals input frequency up to ±4Hz* of the configured 50/60Hz output setting (switches to STANDBY mode if frequency goes outside of this range). *The TRACKING RANGE is factory set to ±4Hz and is user adjustable to ±1Hz, ±2Hz or ±4Hz; The selected TRACKING RANGE setting controls frequency output tolerances as described above in Online, Economy and Bypass modes Output Amp Capacity91A (220/380V); 87A (230/400V); 83A (240/415V) Modular Upgrade OptionsIncludes 2 SVX30PM 30kVA power modules; Up to 2 additional SVX30PM 30kVA power modules can be added for additional capacity or N+1 availability; Add 1 SVX30PM for 90kVA capacity (or 60kVA with N+1 redundancy); Add 2 SVX30PM for 90kVA capacity with N+1 redundancy INPUT Rated input current (Maximum Load)60kVA Configuration: 110A; Maximum 90kVA N+1 Medium Chassis Configuration: 165A; 40A maximum inrush current Nominal Input Voltage(s) Supported220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye Nominal Input Voltage DescriptionSet of two hardwire input connections enables 3-Phase Wye, 4 wire (3P, N, E) inputs from two separate power sources UPS Input Connection TypeHardwire Input Circuit BreakersMAIN and ALTERNATE AC inputs are each protected by 400A 3 pole magnetic breakers Input Phase3-Phase Input Frequency40 to 70Hz (online mode); 50/60Hz Auto-selectable Power Factor (Input)Greater than 0.99 (full load) THDiLess than 3% (full linear load) BATTERY Full Load Runtime (min.)7 minutes (60kW) 3 / 6Half Load Runtime (min.)17 minutes (30kW) Expandable Battery RuntimeSupports extended runtime with optional external battery packs; 100A 3 pole 250VDC breaker recommended for external battery External Battery Pack CompatibilityBP480V200; BP480V300; BP480V400; BP480V500; BP480V370 Expandable Runtime DescriptionExternal battery pack wiring is contractor supplied; All external battery configurations require the disconnection of internal battery modules DC System Voltage (VDC)±240VDC Battery Recharge Rate (Included Batteries) User selectable charging current of 1A to 8A (2A factory setting); Recharge rate is dependent on number of external battery packs connected and the selected charge current setting Battery Replacement DescriptionHot-swappable, replaceable batteries Expandable RuntimeYes VOLTAGE REGULATION Voltage Regulation DescriptionOnline, double-conversion power conditioning Overvoltage CorrectionMaintains continuous output in online mode, without using battery power, during overvoltages to 478V (Ph-Ph), reducing output to within 1% of selected 380/220V, 400/230V, 415/240V nominal output voltage Undervoltage CorrectionMaintains continuous output in online mode, without using battery power, during brownout/undervoltage conditions to 305V (Ph-Ph) at full load and to 208V (Ph-Ph) at 70% output load or less, increasing output to within 1% of selected 380/220V, 400/230V, 415/240V nominal output voltage USER INTERFACE, ALERTS & CONTROLS Front Panel LCD Display145mm front panel LCD display with directional scroll and select buttons offers complete operating status display, plus setting and selection options for all UPS functions SwitchesFront panel buttons include ESC (menu escape), UP/LEFT (menu up / left), DOWN/RIGHT (menu down / right), ENTER (confirm selection), HOME (return to home screen) and POWER (on/off power control); Also includes Manual Bypass switch Alarm Cancel OperationAudible alarms can be muted using on-screen prompts Audible AlarmUnique audible alarms for POWER ON / POWER OFF (alarm sounds for 2 seconds), BATTERY MODE (alarm sounds every 2 seconds), LOW BATTERY (alarm sounds every 0.5 seconds), UPS ALARM (alarm sounds every 1 second), UPS FAULT (continuous alarm) LED IndicatorsFront panel LED indicators represent INPUT (green), BYPASS (amber), INVERTER (green), BATTERY (red) and ALARM (red) SURGE / NOISE SUPPRESSION EMI / RFI AC Noise SuppressionYes AC Suppression Joule Rating2496 AC Suppression Joule Rating Details2496 joules (Ph-Ph), 2496 joules (Ph-N), 1872 joules (N-E) AC Suppression Response TimeInstantaneous PHYSICAL Installation Form Factors Supported with Included AccessoriesTower Primary Form FactorTower 4 / 6UPS Power Module Dimensions (hwd, in.)79.13 x 23.62 x 43.3 UPS Power Module Dimensions (hwd, cm)200.99 x 59.99 x 109.98 UPS Power Module Weight (lbs.)1903 UPS Power Module Weight (kg)863.19 Shipping Dimensions (hwd / in.)54.500 x 28.500 x 42.500 Shipping Dimensions (hwd / cm)138.43 x 72.39 x 107.95 Shipping Weight (lbs.)1058.0000 Shipping Weight (kg)479.90 Cooling MethodFans UPS Housing MaterialSteel Primary UPS Height (mm)20,099 Primary UPS Width (mm)5,999 Primary UPS Depth (mm)10,998 ENVIRONMENTAL Operating Temperature Range0° to +40°C (+32° to +104°F); De-rates to 90% capacity at 35°C / 95°F and 80% capacity at 40°C / 104°F Storage Temperature Range-15° to +60°C (+5° to +140°F) Relative Humidity0 to 95%, non-condensing AC Mode BTU / Hr. (Full Load)11458 AC Economy Mode BTU / Hr. (Full Load)890 AC Mode Efficiency Rating (100% Load)95% AC Economy Mode Efficiency Rating (100% Load)99% Audible NoiseLess than 73 DBA front-side, 1m Operating Elevation (m)Up to 1000m (At elevations over 1000m, output de-rates by 1% per 100m) COMMUNICATIONS Communications InterfaceDB9 Serial; EPO (emergency power off); Pre-installed network card; Slot for SNMP/Web interface Network Management Cards <a class=”productLink” href=”//www.tripplite.com/Web-Management-AccessoryCard~WEBCARDLX”>WEBCARDLX</a> Network Monitoring Port DescriptionIncludes pre-installed Tripp Lite WEBCARDLX network interface PowerAlert SoftwareFor local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert Communications CableDB9 cabling included SNMP CompatibilityIncludes pre-installed <a class=”productLink” href=”//www.tripplite.com/Web-Management-AccessoryCard~WEBCARDLX”>WEBCARDLX</a> network interface card 5 / 6 © 2018 Tripp Lite. All rights reserved. All product and company names are trademarks or registered trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement by them. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Tripp Lite uses primary and third-party agencies to test its products for compliance with standards. See a list of Tripp Lite’s testing agencies: https://www.tripplite.com/products/product-certification-agencies LINE / BATTERY TRANSFER Transfer TimeNo transfer time (0 ms.) in online, double-conversion mode; Less than 20 ms. transfer time in economy mode Low Voltage Transfer to Battery Power (Setpoint) Maintains continuous operation without using battery power during brownout/undervoltage conditions to 305V (PhPh) Full load or 208V (Ph-Ph) 70% load or less; Below the low transfer voltage point, output is maintained utilizing reserve battery power High Voltage Transfer to Battery Power (Setpoint) Maintains continuous operation without using battery power during overvoltages to 478V (Ph-Ph), reducing output within 1% of nominal; Above this point, output is maintained utilizing reserve battery power SPECIAL FEATURES Cold Start (Startup in Battery Mode During a Power Failure)Cold-start operation supported High Availability UPS FeaturesAutomatic inverter bypass; Hot swappable batteries Green Energy-Saving FeaturesGreater than 95% efficiency – GREEN UPS; High efficiency economy mode operation; Schedulable daily hours of economy mode operation CERTIFICATIONS UPS CertificationsCE; ROHS (Restriction of Hazardous Substances) UPS Certification DetailsAgency standards IEC 62040-1:2008+A1:2013; EMI Approvals EN62040-2, 2006 (Category C3); Vibration and Shock: SS-EN 60068-2-64 WARRANTY Product Warranty Period (International)2-year limited warranty
Additional information
Brand |
---|