SmartPro 120V 1.5kVA 1.44kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, USB, 8 Outlets

Sale!

$2,584.31

SmartPro 120V 1.5kVA 1.44kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, USB, 8 Outlets

Add to Wishlist
Add to Wishlist
Compare
SKU: SMART1500CRMXL Category:

Description

Description
The SMART1500CRMXL SmartPro 120V 1.5kVA 1.44kW Line-Interactive Sine Wave UPS provides battery
backup and AC power protection against blackouts, brownouts, power surges and line noise that can damage electronics or destroy data. Ideal for backing up
servers and network storage devices, the SMART1500CRMXL switches to 1.5kVA/1.44kW battery mode in milliseconds to keep your connected equipment
running long enough to save files and shut down safely with no data loss.
Featuring eight NEMA 5-15R outlets (three switchable) and a 10-foot power cord with 120V NEMA 5-15P input, the SMART1500CRMXL has an internal
battery that provides 14 minutes of support at half load and six minutes at full load. Front-panel LEDs indicate line power, battery power, overload, voltage
regulation and battery status. Adding external battery packs, such as Tripp Lite’s BP48V24-2U (sold separately), provides extended runtime.
Automatic voltage regulation (AVR) maintains 120V nominal output over an input range of 83V to 145V without using battery power. EMI/RFI noise filtering
improves your equipment’s performance and prevents damage. A 570-joule surge suppression rating protects your equipment from harmful power surges.
With Tripp Lite’s PowerAlert® software (available via free download), SMART1500CRMXL enables safe unattended system shutdown and file saves in case of
a prolonged power failure.
Features
Protects Mission-Critical Rack-Mounted Equipment
Provides fully regulated sine wave AC output for servers, network storage devices and telecom hardware
Audible alarm signals loss of utility power, overload and low battery
8 NEMA 5-15R outlets
10 ft. power cord with 120V NEMA 5-15P input
570-joule surge suppression rating
Reliable Battery Backup with Expandable Runtime
Supports half load up to 14 min. and full load up to 6 min.
Highlights
Corrects under- and overvoltages
from 83V to 145V
8 NEMA 5-15R outlets—3
switchable via network interface
Network power management and
control capability
Expandable runtime with optional
external battery packs
14 min. runtime at half load; 6
min. at full load
Package Includes
SMART1500CRMXL SmartPro
120V 1.5kVA 1.44kW
Line-Interactive Sine Wave UPS
USB cable
DB9 cable
EPO cable
Mounting hardware
Owner’s manual
1 / 6
Internal batteries designed for hot-swap field replacement
97% line-power efficiency rating saves money in energy costs
Expandable runtime with optional external battery packs, such as Tripp Lite’s BP48V24-2U
3 Load Banks with Switchable Outlets
Can control 3 outlets remotely to reboot equipment or shed nonessential loads
Automatic Voltage Regulation (AVR)
Maintains 120V nominal output over input range of 83V–145V without using battery power
EMI/RFI Line Noise Filtering
Removes electromagnetic and radio frequency interference that can disrupt or damage equipment’s performance
LED Indicators
Front-panel LEDs signal indicate line power, battery power, overload, voltage regulation and battery status
Network Management Cards
Compatible with Tripp Lite UPS management card options WEBCARDLX and SNMPWEBCARD
Communications Ports
USB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite’s PowerAlert software, available via FREE download from
www.tripplite.com/poweralert
EPO port supports emergency shutdown in large facilities
Versatile Installation Options
Hardware included for 4-post mounting in 2U of EIA-standard 19 in. rack
Mounts on wall or 2-post rack with optional 2POSTRMKITWM accessory
Mounts in upright tower position with optional 2-9USTAND accessory
Specifications
OUTPUT
Output Volt Amp Capacity (VA) 1500
Output kVA Capacity (kVA) 1.5
Output Watt Capacity (Watts) 1440
Output kW Capacity (kW) 1.44
Power Factor 1
Nominal Output Voltage(s)
Supported 110V; 115V; 120V
Nominal Voltage Details 120v nominal output in battery mode
Frequency Compatibility 60 Hz
2 / 6
Output Voltage Regulation (Line
Mode) -14%, +8%
Output Voltage Regulation (Battery
Mode) +/- 5%
Output Receptacles (8) 5-15R
Load Management Receptacles Three switchable single-outlet 5-15R load banks
Output AC Waveform (AC Mode) Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
INPUT
Rated input current (Maximum Load) 12A
Nominal Input Voltage(s) Supported 120V AC
UPS Input Connection Type 5-15P
Input Circuit Breakers 15A
UPS Input Cord Length (ft.) 10
UPS Input Cord Length (m) 3.0
Recommended Electrical Service 15A 120V
Input Phase Single-Phase
BATTERY
Full Load Runtime (min.) 6 min. (1440w)
Half Load Runtime (min.) 14 min. (720w)
Expandable Battery Runtime Extended runtime supported via optional external battery packs
External Battery Pack Compatibility BP48V24-2U(limit 1); BP48V60RT-3U(multi-pack compatible); BP48V27-2US(multi-pack compatible)
DC System Voltage (VDC) 48
Battery Recharge Rate (Included
Batteries) Less than 3 hours from 10% to 90% (typical, full load discharge)
Internal UPS Replacement Battery
Cartridge RBC94-2U
Battery Access Front panel battery access door
Battery Replacement Description Hot-swappable, user replaceable batteries
Expandable Runtime Yes
VOLTAGE REGULATION
Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145
Overvoltage Correction Input voltages between 127 and 145 are reduced by 12%
Undervoltage Correction Input voltages between 96 and 108 are boosted by 12%
Severe Undervoltage Correction Input voltages between 83 and 95 are boosted by 24%
3 / 6
USER INTERFACE, ALERTS & CONTROLS
Switches 2 Switches control off/on power status and alarm-cancel/self-test operation; rear panel protected switches support
nominal voltage selection
Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate
low-battery status
Audible Alarm Audible alarm indicates power-failure, overload and low-battery conditions
LED Indicators 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 570
UPS AC Suppression Response
Time Instantaneous
EMI / RFI AC Noise Suppression Yes
PHYSICAL
Included Mounting Accessory
Description 4 post rackmount installation accessories included
Installation Form Factors Supported
with Optional Accessories 2 post rackmount(2POSTRMKITWM); Wallmount(2POSTRMKITWM); Tower(2-9USTAND)
Primary Form Factor Rackmount
UPS Power Module Dimensions
(hwd, in.) 3.43 x 17.3 x 19.4
UPS Power Module Dimensions
(hwd, cm) 8.71 x 43.94 x 49.28
Rack Height (U Spaces) 2
Minimum Required Rack Depth
(inches) 26.4
Minimum Required Rack Depth (cm) 67.06
UPS Power Module Weight (lbs.) 60
UPS Power Module Weight (kg) 27.22
UPS Shipping Dimensions (hwd / in.) 9.2 x 24 x 20
UPS Shipping Dimensions (hwd /
cm) 23.37 x 60.96 x 50.80
Shipping Weight (lbs.) 70.7
Shipping Weight (kg) 32.1
Cooling Method Fan
UPS Housing Material Steel
Minimum Required Rack Depth (mm) 671
Primary UPS Height (mm) 87
4 / 6
Primary UPS Width (mm) 439
Primary UPS Depth (mm) 493
Shipping Height (mm) 234
Shipping Width (mm) 610
Shipping Depth (mm) 508
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load) 152
Battery Mode BTU / Hr. (Full Load) 546
AC Mode Efficiency Rating (100%
Load) 97%
COMMUNICATIONS
Communications Interface USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
Network Management Cards SNMPWEBCARD; WEBCARDLX
Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions
PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at
http://www.tripplite.com/poweralert
Communications Cable USB and DB9 cabling included
WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER
Transfer Time 5.5 milliseconds
Low Voltage Transfer to Battery
Power (Setpoint) 83
High Voltage Transfer to Battery
Power (Setpoint) 145
SPECIAL FEATURES
High Availability UPS Features Hot swappable batteries
Green Energy-Saving Features Greater than 95% efficiency – GREEN UPS; Individually controllable load banks
CERTIFICATIONS
UPS Certifications Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)
WARRANTY
5 / 6
Product Warranty Period (Worldwide) 2-year warranty, 3 year with registration. Note: Registration is required for 3-year warranty.
Connected Equipment Insurance
(U.S., Canada & Puerto Rico) $250,000 Ultimate Lifetime Insurance

Additional information

Weight 30.84 kg
Dimensions 22.09 × 58.42 × 49.02 cm
Brand