SmartPro 120V 2.2kVA 1.92kW UL 60601-1 Medical-Grade Line-Interactive UPS, Extended Run, SNMPWEBCARD Option, Full Isolation, USB, DB9 Serial

Sale!

$3,937.77

SmartPro 120V 2.2kVA 1.92kW UL 60601-1 Medical-Grade Line-Interactive UPS, Extended Run, SNMPWEBCARD Option, Full Isolation, USB, DB9 Serial

Add to Wishlist
Add to Wishlist
Compare
SKU: SMART2500XLHG Category:

Description

Tripp-Lite SMART2500XLHG | SmartPro 120V 2.2kVA 1.92kW UL 60601-1 Medical-Grade Line-Interactive UPS, Extended Run, SNMPWEBCARD Option, Full Isolation, USB, DB9 Serial

https://www.alldataresource.com/assets/images_commscope/features.jpg

Features

  • Ideal UPS protection for applications in patient-care vicinities where UL 60601-1 3rd edition listed medical electrical equipment is required
  • Internal low-impedance isolation transformer with Faraday shield offers 100% isolation from the input AC line
  • Floating AC output prevents noise coupling from noisy hospital ground circuits
  • Full line isolation prevents shock potential and operational problems in sensitive electronic equipment
  • Provides connected equipment with continuous power during short and long duration loss of commercial power
  • Expandable runtime is available with the addition of one or more external battery packs (BP48V24-2U and BP24V60RT-3U)
  • Line-interactive voltage regulation corrects brownouts and overvoltages from 83V to 143V back to usable 120V output levels without using battery power
  • Resistant to electrostatic discharge
  • Supports loads up to 2200VA/1920W
  • 13 min. half-load runtime (1100VA/960W), 4 min. full load runtime (2200VA/1920W)
  • Input: IEC320-C20 inlet with locking clamp; Output: 4 NEMA 5-15/20R and 4 IEC C13
  • Built-in USB, DB9 (RS-232) and optional SNMPWEBCARD accessory monitoring options
  • PowerAlert unattended shutdown software and complete cabling included
  • Offers line isolation and continuous noise filtering
  • 940-joule surge protection rating
  • 5 diagnostic LEDs indicate AC present, on battery, voltage correction, overload & battery low/replace
  • Battery replacement door and back panel grounding lug
  • Relay I/O card allows users to communicate UPS status and events via 6 configurable contact closure outputs
https://www.alldataresource.com/assets/images_tripplite/overview.jpg

Overview

UPC Code 37332168283
UPS Type Line-Interactive
https://www.alldataresource.com/assets/images_commscope/specs.jpg

Input

Rated input current (Maximum Load) 16 AMP
Nominal Input Voltage(s) Supported 120V AC
UPS Input Connection Type C20 inlet
Input Circuit Breakers 2 x 20A
UPS Input Cord Length (ft.) 6
Recommended Electrical Service 20A 120V
https://www.alldataresource.com/assets/images_commscope/specs.jpg

Output

Output Volt Amp Capacity (VA) 2200
Output kVA Capacity (kVA) 2.2
Output Watt Capacity (Watts) 1920
Power Factor 0.87
Frequency Compatibility 60 Hz
Output Voltage Regulation (Line Mode) -18%, +8%
Output Voltage Regulation (Battery Mode) 115V (+/- 5%)
Output Receptacle Details Hospital grade output receptacles
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
https://www.alldataresource.com/assets/images_commscope/specs.jpg

Battery

Battery Type Valve Regulated Lead Acid (VRLA)
Full Load Runtime (min.) 4.4 minutes
Half Load Runtime (min.) 13 minutes
Expandable Battery Runtime Extended runtime supported via optional external battery packs
Expandable Runtime Yes
https://www.alldataresource.com/assets/images_commscope/specs.jpg

Voltage Regulation

Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 81 to 143
Overvoltage Correction Input voltages between 126 and 143 are reduced by 9%
https://www.alldataresource.com/assets/images_commscope/specs.jpg

User Interface, Alerts & Controls

Switches 2 Switches control off/on power status and alarm-cancel/self-test operation
Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
Audible Alarm Audible alarm indicates power-failure, overload and low-battery conditions
https://www.alldataresource.com/assets/images_commscope/specs.jpg

Surge / Noise Suppression

UPS AC Suppression Joule Rating 940
UPS AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression Yes
https://www.alldataresource.com/assets/images_commscope/specs.jpg

Isolation

Output Isolation Transformer Hospital grade load isolation transformer
Leakage Current Equal to 100 microamps
https://www.alldataresource.com/assets/images_tripplite/physical_specifications.jpg

Physical

Cooling Method Fan
Installation Form Factors Supported with Included Accessories Tower
Installation Form Factors Supported with Optional Accessories Wallmount ( UPSWM  – tower mounting kit)
https://www.alldataresource.com/assets/images_commscope/specs.jpg

Environmental

Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%; non-condensing
AC Mode BTU / Hr. (Full Load) 162.8
Battery Mode BTU / Hr. (Full Load) 315.2
AC Mode Efficiency Rating (100% Load) 0.94
https://www.alldataresource.com/assets/images_commscope/specs.jpg

Communications

Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions
PowerAlert Software For local monitoring via the UPS’s built-in communication ports ; download PowerAlert Local software at https://www.tripplite.com/poweralert
Communications Cable USB and DB9 serial cabling included
Communications Interface USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
https://www.alldataresource.com/assets/images_commscope/specs.jpg

Line / Battery Transfer

Transfer Time 2-4 milliseconds
Low Voltage Transfer to Battery Power (Setpoint) 81
High Voltage Transfer to Battery Power (Setpoint) 143

Additional information

Weight 45.35 kg
Dimensions 40.64 × 35.56 × 60.96 cm
Brand