Sale!
Compare
KShs213,613.01
SmartPro 230V 1kVA 750W Medical-Grade Line-Interactive Tower UPS with 6 Outlets, Full Isolation, Expandable Runtime
Description
Specifications
OVERVIEW
UPC Code | 037332140425 |
UPS Type | Line-Interactive |
INPUT
Rated input current (Maximum Load) | 5A |
Nominal Input Voltage(s) Supported | 230V AC |
UPS Input Connection Type | C14 inlet |
UPS Input Cord Length (ft.) | 0.50 |
UPS Input Cord Length (m) | 0.2 |
Recommended Electrical Service | 10A 230V |
Voltage Compatibility (VAC) | 230 |
Input Phase | Single-Phase |
OUTPUT
Output Volt Amp Capacity (VA) | 1000 |
Output Watt Capacity (Watts) | 750 |
Nominal Voltage Details | 230v nominal inverter output voltage |
Frequency Compatibility | 50 / 60 Hz |
Frequency Compatibility Details | Automatic frequency selection |
Output Voltage Regulation (Line Mode) | -18%, +8% |
Output AC Waveform (Battery Mode) | PWM sine wave |
Nominal Output Voltage(s) Supported | 220V; 230V; 240V |
Output Receptacles | (6) C13 |
Individually Controllable Load Banks | No |
BATTERY
Battery Type | Valve Regulated Lead Acid (VRLA) |
Full Load Runtime (min.) | 11 min. (750w) |
Half Load Runtime (min.) | 27.5 min. (375w) |
Expandable Battery Runtime | Supports extended runtime with optional BP36V15-2U (limit 1) and BP36V42-3U external battery pack (multi-pack compatible) |
Expandable Runtime | Yes |
External Battery Pack Compatibility | BP36V15-2U (limit 1); BP36V42-3U (multi-pack compatible); BP36V27-2US (multi-pack compatible) |
DC System Voltage (VDC) | 36 |
Battery Recharge Rate (Included Batteries) | Less than 4.5 hours from 10% to 90% |
Battery Access | Battery access door allows hot swap battery replacement without powering connected equipment off |
Internal UPS Replacement Battery Cartridge | RBC36SLT |
Typical Battery Lifespan | 3-6 years, depending on usage |
VOLTAGE REGULATION
Voltage Regulation Description | Line interactive UPS offers 2 boost levels of brownout correction and a single level of overvoltage adjustment to maintain usable, computer grade output without consuming battery power over an input voltage range of 155 to 274V AC. |
Overvoltage Correction | Input voltages between 245 and 274V AC are reduced by 9% |
Undervoltage Correction | Input voltages between 183 and 199 are boosted by 10% |
Severe Undervoltage Correction | Input voltages between 156 and 182 are boosted by 21% |
USER INTERFACE, ALERTS & CONTROLS
Switches | Yes, includes 2 front panel mounted push-button switches for system enable, self-test and alarm cancel functions |
Audible Alarm | Audible Alarm is factory muted for silent operation; Audible alarm can be restored to indicate power failure, overload conditions and Low Battery events using our Free Power Alert UPS management software. |
LED Indicators | 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating | 340 |
EMI / RFI AC Noise Suppression | Yes |
AC Suppression Response Time | Instantaneous |
PHYSICAL
Primary Form Factor | Tower |
Cooling Method | UPS cooling via rear-exit fan |
Installation Form Factors Supported with Included Accessories | Tower |
Installation Form Factors Supported with Optional Accessories | Wallmount ( UPSWM – tower mounting kit) |
Primary UPS Depth (mm) | 231 |
Primary UPS Height (mm) | 323 |
Primary UPS Width (mm) | 191 |
Shipping Dimensions (hwd / cm) | 46.99 x 30.99 x 33.99 |
Shipping Weight (kg) | 22.14 |
UPS Housing Material | PVC |
UPS Power Module Dimensions (hwd, cm) | 32.26 x 19.05 x 23.11 |
UPS Power Module Weight (kg) | 20.64 |
ENVIRONMENTAL
Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Relative Humidity | 0 to 95%, non-condensing |
AC Mode BTU / Hr. (Full Load) | 252.2 |
Battery Mode BTU / Hr. (Full Load) | 252.2 |
COMMUNICATIONS
Network Management Card Description | Network management not supported |
Communications Interface | USB; DB9 Serial |
LINE / BATTERY TRANSFER
Transfer Time | 2-4 milliseconds |
Low Voltage Transfer to Battery Power (Setpoint) | 155 |
High Voltage Transfer to Battery Power (Setpoint) | 274 |
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
High Availability UPS Features | Surge/noise protection |
Grounding Lug | Ground Potential Equalization Connector: POAG-S6/20 |
STANDARDS & COMPLIANCE
Product Certifications | UL 60601-1 |
Product Compliance | RoHS; CE (Europe) |
WARRANTY
Product Warranty Period (International) | 2-year limited warranty |
Additional information
Weight | 22.13 kg |
---|---|
Dimensions | 46.99 × 30.98 × 33.98 cm |
Brand |