OVERVIEW
UPC Code 037332140425
UPS Type Line-Interactive
INPUT
Rated input current (Maximum Load) 5A
Nominal Input Voltage(s) Supported 230V AC
UPS Input Connection Type C14 inlet
UPS Input Cord Length (ft.) 0.50
UPS Input Cord Length (m) 0.2
Recommended Electrical Service 10A 230V
Voltage Compatibility (VAC) 230
Input Phase Single-Phase
OUTPUT
Output Volt Amp Capacity (VA) 1000
Output Watt Capacity (Watts) 750
Nominal Voltage Details 230v nominal inverter output voltage
Frequency Compatibility 50 / 60 Hz
Frequency Compatibility Details Automatic frequency selection
Output Voltage Regulation (Line Mode) -18%, +8%
Output AC Waveform (Battery Mode) PWM sine wave
Nominal Output Voltage(s) Supported 220V; 230V; 240V
Output Receptacles (6) C13
Individually Controllable Load Banks No
BATTERY
Battery Type Valve Regulated Lead Acid (VRLA)
Full Load Runtime (min.) 11 min. (750w)
Half Load Runtime (min.) 27.5 min. (375w)
Expandable Battery Runtime Supports extended runtime with optional  BP36V15-2U  (limit 1) and  BP36V42-3U  external battery pack (multi-pack compatible)
Expandable Runtime Yes
External Battery Pack Compatibility  BP36V15-2U  (limit 1);  BP36V42-3U  (multi-pack compatible);  BP36V27-2US  (multi-pack compatible)
DC System Voltage (VDC) 36
Battery Recharge Rate (Included Batteries) Less than 4.5 hours from 10% to 90%
Battery Access Battery access door allows hot swap battery replacement without powering connected equipment off
Internal UPS Replacement Battery Cartridge RBC36SLT
Typical Battery Lifespan 3-6 years, depending on usage
VOLTAGE REGULATION
Voltage Regulation Description Line interactive UPS offers 2 boost levels of brownout correction and a single level of overvoltage adjustment to maintain usable, computer grade output without consuming battery power over an input voltage range of 155 to 274V AC.
Overvoltage Correction Input voltages between 245 and 274V AC are reduced by 9%
Undervoltage Correction Input voltages between 183 and 199 are boosted by 10%
Severe Undervoltage Correction Input voltages between 156 and 182 are boosted by 21%
USER INTERFACE, ALERTS & CONTROLS
Switches Yes, includes 2 front panel mounted push-button switches for system enable, self-test and alarm cancel functions
Audible Alarm Audible Alarm is factory muted for silent operation; Audible alarm can be restored to indicate power failure, overload conditions and Low Battery events using our Free Power Alert UPS management software.
LED Indicators 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 340
EMI / RFI AC Noise Suppression Yes
AC Suppression Response Time Instantaneous
PHYSICAL
Primary Form Factor Tower
Cooling Method UPS cooling via rear-exit fan
Installation Form Factors Supported with Included Accessories Tower
Installation Form Factors Supported with Optional Accessories Wallmount ( UPSWM  – tower mounting kit)
Primary UPS Depth (mm) 231
Primary UPS Height (mm) 323
Primary UPS Width (mm) 191
Shipping Dimensions (hwd / cm) 46.99 x 30.99 x 33.99
Shipping Weight (kg) 22.14
UPS Housing Material PVC
UPS Power Module Dimensions (hwd, cm) 32.26 x 19.05 x 23.11
UPS Power Module Weight (kg) 20.64
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load) 252.2
Battery Mode BTU / Hr. (Full Load) 252.2
COMMUNICATIONS
Network Management Card Description Network management not supported
Communications Interface USB; DB9 Serial
LINE / BATTERY TRANSFER
Transfer Time 2-4 milliseconds
Low Voltage Transfer to Battery Power (Setpoint) 155
High Voltage Transfer to Battery Power (Setpoint) 274
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features Surge/noise protection
Grounding Lug Ground Potential Equalization Connector: POAG-S6/20
STANDARDS & COMPLIANCE
Product Certifications UL 60601-1
Product Compliance RoHS; CE (Europe)
WARRANTY
Product Warranty Period (International) 2-year limited warranty

Additional information

Weight 22.13 kg
Dimensions 46.99 × 30.98 × 33.98 cm