SmartPro 230V 1kVA 900W Line-Interactive Sine Wave UPS, 2U Rack/Tower, Network Card Options, LCD, USB, DB9, 6 Outlets

Sale!

KShs177,852.35

SmartPro 230V 1kVA 900W Line-Interactive Sine Wave UPS, 2U Rack/Tower, Network Card Options, LCD, USB, DB9, 6 Outlets

Add to Wishlist
Add to Wishlist
Compare
SKU: SMX1000RT2U Category:

Description

Specifications

OVERVIEW
UPC Code 037332119223
UPS Type Line-Interactive
INPUT
Rated input current (Maximum Load) 4.8A
Nominal Input Voltage(s) Supported 230V AC
UPS Input Connection Type C14 inlet
UPS Input Connection Description IEC320-C14 input connection accepts a variety of detachable cordsets to match country or site-specific wall receptacles
Input Circuit Breakers 10A
Input Phase Single-Phase
OUTPUT
Output Volt Amp Capacity (VA) 1000
Output Capacity (kVA) 1
Output Watt Capacity (Watts) 900
Power Factor 0.9
Nominal Voltage Details 230V nominal output in battery mode
Frequency Compatibility 50 / 60 Hz
Frequency Compatibility Details Automatic frequency selection
Output Voltage Regulation (Line Mode) +6%, -11%
Output Voltage Regulation (Battery Mode) +/- 5%
Included Output Power Cables Includes 2 C13 to C14 output power cables
Load Management Receptacles Two switchable two-outlet C13 load banks
Hot-Swap PDU options PDUBHV10 (2U / 8 C13 outlets)
Output AC Waveform (AC Mode) Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Nominal Output Voltage(s) Supported 220V; 230V; 240V
Output Receptacles (6) C13
Individually Controllable Load Banks Yes
BATTERY
Battery Type Valve Regulated Lead Acid (VRLA)
Full Load Runtime (min.) 3.6 min. (900w)
Half Load Runtime (min.) 11.9 min (450w)
Expandable Runtime No
DC System Voltage (VDC) 24
Battery Recharge Rate (Included Batteries) Less than 4.5 hours from 10% to 90% (typical, full load discharge)
Battery Access Front panel battery access door
Internal UPS Replacement Battery Cartridge IMPORTANT BATTERY REPLACEMENT INFORMATION > If your SMX1000RT2U UPS is equipped with a LCD front-panel screen, order Tripp Lite  RBC24V-LCD  (quantity 1) replacement battery; If your SMX1000RT2U UPS is equipped with LED front-panel indicators, order Tripp Lite  RBC92-2U  (quantity 1) replacement battery
Battery Replacement Description Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 182 to 278
Overvoltage Correction Input voltages between 244 and 278 are reduced by 12%
Undervoltage Correction Input voltages between 182 and 206 are boosted by 12%
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)
Switches 3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions
Alarm Cancel Operation Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
Audible Alarm Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 350
UPS AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression Yes
PHYSICAL
Primary Form Factor Rackmount
Rack Height 2U
Cooling Method Fan
Included Mounting Accessory Description Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)
Installation Form Factors Supported with Included Accessories 4 post 19 inch rackmount
Installation Form Factors Supported with Optional Accessories 2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM )
Minimum Required Rack Depth (cm) 40.00
Optional Mounting Accessory Notes Optional  2-9USTAND  enables upright tower UPS placement;  2POSTRMKITWM  enables wall-mount and 2-post rackmount installation;  4POSTRAILKITWM  enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm);  UPSHDEARKIT  enables installation in 2 or 4-post racks using front vertical rails only, without rear support
Primary UPS Depth (mm) 343
Primary UPS Height (mm) 89
Primary UPS Width (mm) 445
Shipping Dimensions (hwd / cm) 21.59 x 58.67 x 46.23
Shipping Weight (kg) 20.82
UPS Housing Material Steel
UPS Power Module Dimensions (hwd, cm) 8.89 x 44.45 x 34.29
UPS Power Module Weight (kg) 15.42
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load) 100
Battery Mode BTU / Hr. (Full Load) 918
AC Mode Efficiency Rating (100% Load) 97%
Audible Noise 45 dBA maximum, front side 1m
COMMUNICATIONS
Network Management Cards SNMPWEBCARD;  TLNETCARD ;  WEBCARDLX
Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions
PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://www.tripplite.com/poweralert
Communications Cable USB and DB9 cabling included
WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
Network Management Card Description Network management card optional
Communications Interface DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)
LINE / BATTERY TRANSFER
Transfer Time 2-4 milliseconds
Low Voltage Transfer to Battery Power (Setpoint) 182
High Voltage Transfer to Battery Power (Setpoint) 278
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features Auto Probe Monitoring and Reboot (requires WEBCARDLX); Automatic Voltage Regulation (AVR); Hot swappable batteries; Remote management; Sine wave output; Surge/noise protection
Green Energy-Saving Features Greater than 95% efficiency – GREEN UPS; Individually controllable load banks
Grounding Lug Back panel grounding lug
STANDARDS & COMPLIANCE
Product Certifications GOST (Russia); IEC/EN 62040
Product Compliance RoHS; CE (Europe)
WARRANTY
Product Warranty Period (International) 2-year limited warranty

Additional information

Weight 20.81 kg
Dimensions 21.59 × 58.67 × 46.22 cm
Brand