Sale!
	
	
		
	
            
			
	
	
	
Compare
	
	
	
		
					
				
	
			
					
				
	
			
			
		
			
	
	
			$1,379.21
SmartPro 230V 700VA 450W Medical-Grade Line-Interactive Tower UPS with 6 Outlets, Full Isolation, USB, DB9
Description
Specifications
OVERVIEW
| UPC Code | 037332140418 | 
| UPS Type | Line-Interactive | 
INPUT
| Rated input current (Maximum Load) | 3.6A | 
| Nominal Input Voltage(s) Supported | 230V AC | 
| UPS Input Connection Type | C14 inlet | 
| UPS Input Cord Length (ft.) | 0.50 | 
| UPS Input Cord Length (m) | 0.2 | 
| Recommended Electrical Service | 10A 230V | 
| Voltage Compatibility (VAC) | 230 | 
| Input Phase | Single-Phase | 
OUTPUT
| Output Volt Amp Capacity (VA) | 700 | 
| Output Watt Capacity (Watts) | 450 | 
| Nominal Voltage Details | 230v nominal inverter output voltage | 
| Frequency Compatibility | 50 / 60 Hz | 
| Frequency Compatibility Details | Automatic frequency selection | 
| Output Voltage Regulation (Line Mode) | -18%, +8% | 
| Output AC Waveform (Battery Mode) | PWM sine wave | 
| Nominal Output Voltage(s) Supported | 220V; 230V; 240V | 
| Output Receptacles | (6) C13 | 
| Individually Controllable Load Banks | No | 
BATTERY
| Battery Type | Valve Regulated Lead Acid (VRLA) | 
| Full Load Runtime (min.) | 14.5 min. (450w) | 
| Half Load Runtime (min.) | 36 min. (225w) | 
| Expandable Runtime | No | 
| DC System Voltage (VDC) | 36 | 
| Battery Recharge Rate (Included Batteries) | Less than 3.6 hours from 10% to 90% (typical, full load discharge) | 
| Battery Access | Battery access door allows hot swap battery replacement without powering connected equipment off | 
| Internal UPS Replacement Battery Cartridge | RBC36SLT | 
| Typical Battery Lifespan | 3-6 years, depending on usage | 
VOLTAGE REGULATION
| Voltage Regulation Description | Line interactive UPS offers 2 boost levels of brownout correction and a single level of overvoltage adjustment to maintain usable, computer grade output without consuming battery power over an input voltage range of 155 to 274V AC | 
| Overvoltage Correction | Input voltages between 206 and 245V AC are reduced by 9% | 
| Undervoltage Correction | Input voltages between 183 and 199 are boosted by 10% | 
| Severe Undervoltage Correction | Input voltages between 155 and 182 are boosted by 21% | 
USER INTERFACE, ALERTS & CONTROLS
| Switches | Yes, includes 2 front panel mounted push-button switches for system enable, self-test and alarm cancel functions | 
| Audible Alarm | 3 function audible alarm indicates power failure conditions (4 short beeps every 10 seconds), overload (continuous short beeps) and low battery (continuous tone). Audible Alarm is factory muted for silent operation; Audible alarm can be restored to indicate power failure, overload conditions and Low Battery events, using our Free PowerAlert UPS management software. | 
| LED Indicators | 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status | 
SURGE / NOISE SUPPRESSION
| UPS AC Suppression Joule Rating | 340 | 
| EMI / RFI AC Noise Suppression | Yes | 
| AC Suppression Response Time | Instantaneous | 
PHYSICAL
| Primary Form Factor | Tower | 
| Cooling Method | Cooling via rear-exit cooling fan | 
| Installation Form Factors Supported with Included Accessories | Tower | 
| Installation Form Factors Supported with Optional Accessories | Wallmount ( UPSWM – tower mounting kit) | 
| Primary UPS Depth (mm) | 229 | 
| Primary UPS Height (mm) | 325 | 
| Primary UPS Width (mm) | 191 | 
| Shipping Dimensions (hwd / cm) | 46.99 x 30.99 x 33.99 | 
| Shipping Weight (kg) | 20.59 | 
| UPS Housing Material | PVC | 
| UPS Power Module Dimensions (hwd, cm) | 32.51 x 19.05 x 22.86 | 
| UPS Power Module Weight (kg) | 19.10 | 
ENVIRONMENTAL
| Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius | 
| Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius | 
| Relative Humidity | 0 to 95%, non-condensing | 
| AC Mode BTU / Hr. (Full Load) | 208.6 | 
| Battery Mode BTU / Hr. (Full Load) | 189.1 | 
COMMUNICATIONS
| Network Management Card Description | Network management not supported | 
| Communications Interface | USB; DB9 Serial | 
LINE / BATTERY TRANSFER
| Transfer Time | 5 milliseconds | 
| Low Voltage Transfer to Battery Power (Setpoint) | 155 | 
| High Voltage Transfer to Battery Power (Setpoint) | 274 | 
FEATURES & SPECIFICATIONS
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported | 
| High Availability UPS Features | Surge/noise protection | 
| Grounding Lug | Equipotential connection (back panel grounding lug) | 
STANDARDS & COMPLIANCE
| Product Certifications | UL 60601-1 | 
| Product Compliance | RoHS; CE (Europe) | 
WARRANTY & SUPPORT
| Product Warranty Period (International) | 2-year limited warranty | 
Additional information
| Weight | 20.59 kg | 
|---|---|
| Dimensions | 46.99 × 30.98 × 33.98 cm | 
| Brand | 