Tripplite SmartOnline Double-Conversion UPS – 2U, USB, DB9, 230V, 3kVA, 2.5kW, On-Line

Sale!

KShs227,850.00

Features
Double-Conversion UPS Protects Equipment against Damage, Downtime and Data Loss
This 230V 2U UPS system protects connected equipment against damage, downtime and data loss due to power outages, voltage fluctuations and transient surges. Featuring a 2500W capacity, high 0.8 power factor, 420 joules of surge suppression, true on-line operation with pure sine wave output and zero transfer time to battery, the SmartOnline® SUINT3000RTXL2U double-conversion UPS provides the highest level of battery backup and AC power protection for critical network closet, computer room and data center equipment.
Individually Controllable Load Banks Let You Access and Control Outlets
Eight C13 outlets are even split into two switchable load banks, each allowing you to reboot connected equipment or shed loads remotely. In addition to the C13 outlets, this UPS provides two C19 outlets for powering critical components.
Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages
UPS battery backup keeps connected equipment operational through short power failures, and provides time to save data and perform an orderly system shutdown in case of a prolonged blackout. The field-replaceable, hot-swappable internal battery provides 15 minutes of support at half load and six minutes at full load. During normal operation, incoming utility power keeps the battery fully charged so backup power will be available when needed. For mission-critical applications demanding continuous uptime, the 3kVA UPS can provide expandable runtime with optional external battery packs, such as Tripp Lite’s BP72V15-2U (sold separately).
Easily Hot-Swappable with No Expensive Service Calls or Downtime Needed
Tripp Lite’s optional PDUBHV20 bypass PDU (sold separately) enables hot-swappable UPS replacement with no disruption of power to connected equipment. When making repairs or replacing a battery, no lengthy service calls or downtime are necessary.
Optional WEBCARDLX Network Interface Offers 24/7 Remote Access for Monitoring and Control
The optional WEBCARDLX (sold separately) with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and Tripp Lite’s PowerAlert Element Manager (PAEM) software form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations. Auto Probe allows a UPS with switched loads to automatically reboot devices if a network communication failure is detected. This preserves uptime and minimizes the time and expense associated with on-site support.
Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring
Front-panel LEDs provide information on load and battery levels, operating mode, fault status and other critical data at a glance. The LED panel rotates for comfortable viewing in rack-mount or tower configuration.
Advanced Communications Ports
This USB UPS system has USB and DB9 ports (cables are included) that enable data-saving unattended shutdown of connected systems when used with Tripp Lite’s free downloadable PowerAlert® software. Capabilities include detailed monitoring of load levels, self-test data and utility power conditions.
Versatile Installation Options
Hardware is included for mounting the UPS system in 2U of space in an EIA-standard 19-inch 4-post rack with a depth of only 66 centimeters (26 inches). Use the optional 2POSTRMKITWM (sold separately) for 2-post rack mounting or the optional 2-9USTAND (sold separately) for mounting in an upright tower position. The C20 power inlet accepts a variety of user-supplied input cords.
Typical Applications
Deliver perfectly regulated sine wave output to mission-critical equipment
Protect connected components from dangerous surges, spikes and line noise
Keep equipment operational through short power failures
Allow time to save data and safely shut down components in case of a prolonged blackout
Package Includes
SUINT3000RTXL2U SmartOnline Double-Conversion UPS
C19 to C20 power cable, 5 ft.
USB cable
DB9 cable
EPO cable
Rack-mounting hardware
Owner’s manual

Add to Wishlist
Add to Wishlist
Compare
Category:

Description

Specifications
OVERVIEW
UPC Code 037332198495
UPS Type On-Line
INPUT
Rated input current (Maximum Load) 15A
Nominal Input Voltage(s) Supported 230V AC
Nominal Input Voltage Description 230V factory configuration
UPS Input Connection Type C20 inlet
UPS Input Cord Length (ft.) 5
UPS Input Cord Length (m) 1.5
Input Phase Single-Phase
OUTPUT
Output Volt Amp Capacity (VA) 3000
Output kVA Capacity (kVA) 3
Output Watt Capacity (Watts) 2500
Output kW Capacity (kW) 2.5
Output Capacity Details OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes, 150% for 30 seconds and >150% for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits of ±10% and ±5Hz) or SHUTDOWN (when bypass input voltage and frequency are OUTSIDE bypass limits of ±10% and ±5Hz)
Power Factor 0.83
Crest Factor 3:1
Nominal Voltage Details 230V default
Frequency Compatibility 50 / 60 Hz
Frequency Compatibility Details Output frequency matches input nominal on startup, defaults to 50 Hz on cold-start
Output Voltage Regulation (Line Mode) +/- 2%
Output Voltage Regulation (Economy Line Mode) +/-10%
Output Voltage Regulation (Battery Mode) +/- 2%
Included Output Power Cables Includes 2 C13 to C14 and 1 C19 to C20 power cables
Load Management Receptacles Two switchable 4 C13 outlet load banks
Hot-Swap PDU options PDUBHV20 (2U / 6 C13, 2 C19 outlets)
Output AC Waveform (AC Mode) Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Nominal Output Voltage(s) Supported 230V
Output Receptacles (8) C13; (2) C19
Individually Controllable Load Banks Yes
BATTERY
Battery Type Valve Regulated Lead Acid (VRLA)
Full Load Runtime (min.) 6 min. (2500w)
Half Load Runtime (min.) 15 min. (1250w)
Expandable Battery Runtime Supports extended runtime with optional external battery packs
Expandable Runtime Yes
External Battery Pack Compatibility BP72V15-2U (limit 1); BP72V28RT-3U (multi-pack compatible); BP72V18-2US (multi-pack compatible)
DC System Voltage (VDC) 72
Battery Recharge Rate (Included Batteries) Less than 4.8 hours from 10% to 90% (typical, full load discharge)
Battery Access Front panel battery access door
Internal UPS Replacement Battery Cartridge See RBC selector
Battery Replacement Description Hot-swappable, replaceable batteries
VOLTAGE REGULATION
Voltage Regulation Description Online, double-conversion power conditioning
Overvoltage Correction 2% output voltage regulation during overvoltages to 288
Undervoltage Correction 2% output voltage regulation during undervoltages to 160V (70-100% load) / 130V (30-70% load) / 100V (Under 30% load)
USER INTERFACE, ALERTS & CONTROLS
Switches 2 Switches control off/on power status and alarm-cancel/self-test operation
Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch
Audible Alarm Audible alarm indicates power failure, low battery, overload, replace battery and EPO operation
LED Indicators 14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 570
EMI / RFI AC Noise Suppression Yes
AC Suppression Response Time Instantaneous
PHYSICAL
Primary Form Factor Rackmount
Cooling Method Fan
Included Mounting Accessory Description Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)
Installation Form Factors Supported with Included Accessories 4 post 19 inch rackmount
Installation Form Factors Supported with Optional Accessories 2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM )
Minimum Required Rack Depth with External Battery Pack (cm) 77
Minimum Required Rack Depth with External Battery Pack (in.) 30.25
Minimum Required Rack Depth without External Battery Pack (cm) 75
Minimum Required Rack Depth without External Battery Pack (in.) 29.5
Optional Mounting Accessory Notes Optional 2-9USTAND enables upright tower UPS placement; 2POSTRMKITWM enables wall-mount and 2-post rackmount installation; 4POSTRAILKITWM enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm); UPSHDEARKIT enables installation in 2 or 4-post racks using front vertical rails only, without rear support
Primary UPS Depth (mm) 616
Primary UPS Height (mm) 88
Primary UPS Width (mm) 438
Rack Height 2U
Shipping Dimensions (hwd / cm) 24.64 x 60.20 x 75.69
Shipping Weight (kg) 38.42
UPS Housing Material Steel
UPS Power Module Dimensions (hwd, cm) 8.79 x 43.79 x 61.60
UPS Power Module Weight (kg) 31.17
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
Relative Humidity 5 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load) 742
AC Mode Efficiency Rating (100% Load) 92%
COMMUNICATIONS
Network Management Cards WEBCARDLX
Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications
PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
Communications Cable USB and DB9 cabling included
WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
Network Management Card Description Network management card optional
Communications Interface Contact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)
LINE / BATTERY TRANSFER
Transfer Time No transfer time (0 ms.) in online, double-conversion mode
Low Voltage Transfer to Battery Power (Setpoint) 160V (70-100% load), 130V (30-70% load), 100V (less than 33% load)
High Voltage Transfer to Battery Power (Setpoint) 288V
FEATURES & SPECIFICATIONS
Grounding Lug Grounding screw
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features Auto Probe Monitoring and Reboot (requires WEBCARDLX); Automatic inverter bypass; Expandable battery backup; Hot swappable batteries; On-Line/Double-Conversion; Remote management; Sine wave output; Surge/noise protection; Zero transfer time
Green Energy-Saving Features High efficiency economy mode operation; Individually controllable load banks
STANDARDS & COMPLIANCE
UPS Certifications CE; Meets FCC Part 15 Category A (EMI); REACH (Contains No SVHCs); ROHS (Restriction of Hazardous Substances); Tested to CSA (Canada); Tested to EAC (Belarus, Kazakhstan, Russia); Tested to RETIE (Colombia); Tested to UL1778 (USA)
Certification Details Series Number (s) AG-0264; Agency Standard Tested IEC62040-1:2008+A1:2013, UL1778: 2014 5th EDITION; Canadian Approvals CAN/CSA-C22.2 NO. 107.3:2014 3rd EDITION; CE Approvals YES; EMI Approvals EN62040-2:2006, FCC CLASS A
WARRANTY
Product Warranty Period (Worldwide) 2-year limited warranty

Additional information

Brand