OVERVIEW
| UPC Code | 037332192462 | 
| UPS Type | On-Line | 
INPUT
| Rated input current (Maximum Load) | 48.9A | 
| Nominal Input Voltage(s) Supported | 220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye | 
| Nominal Input Voltage Description | 3-Phase Wye, 4 wire plus ground (L1, L2, L3, N, G) | 
| UPS Input Connection Type | Hardwire | 
| Input Circuit Breakers | 63A (3 pole) | 
| Input Phase | 3-Phase | 
| Power Factor (Input) | .99PF (100% load) | 
| THDi | <6% (100% load) | 
OUTPUT
| Output Volt Amp Capacity (VA) | 30000 | 
| Output Capacity (kVA) | 30 | 
| Output Watt Capacity (Watts) | 27000 | 
| Output kW Capacity (kW) | 27 | 
| Output Capacity Details | Supports up to 100% load continuously in double conversion mode; Supports 100-110% load for 10 minutes, 110 to 130% load for 1 minute and greater than 130% for 1 second before switching to bypass mode; Inverter mode is automatically restored as load levels are reduced to 70% or less; Configuration options support up to 3 SVT30KX systems wired in parallel for increased capacity. | 
| Power Factor | 0.9 | 
| Crest Factor | 3:1 | 
| Frequency Compatibility | 50 / 60 Hz | 
| Frequency Compatibility Details | Automatic frequency selection | 
| Output Voltage Regulation (Line Mode) | +/- 1% | 
| Output Voltage Regulation (Economy Line Mode) | +/-11V of selected nominal output voltage (220V: 209-231V; 230V: 219-241; 240V: 229-251V) | 
| Output Voltage Regulation (Battery Mode) | +/- 2% | 
| Output AC Waveform (AC Mode) | Pure Sine wave | 
| Output AC Waveform (Battery Mode) | Pure Sine wave | 
| Nominal Output Voltage(s) Supported | 220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye | 
| Output Receptacles | Hardwire | 
| Individually Controllable Load Banks | No | 
BATTERY
| Full Load Runtime (min.) | 4.2 min (27kW) | 
| Half Load Runtime (min.) | 9.6 min. (13.5kW) | 
| Expandable Battery Runtime | Supports extended runtime optional external battery packs | 
| Expandable Runtime | Yes | 
| External Battery Pack Compatibility | BP240V135 | 
| DC System Voltage (VDC) | 240 | 
| Battery Recharge Rate (Included Batteries) | 4 hours to 90% (Internal batteries) | 
VOLTAGE REGULATION
| Voltage Regulation Description | Online, double-conversion power conditioning maintains output within 1% of the selected nominal voltage in online mode | 
| Overvoltage Correction | Corrects overvoltage conditions to 520V (50% load) and 478V (100% load) | 
| Undervoltage Correction | Corrects brownout conditions to 110V (50% load) / 305V (100% load) | 
USER INTERFACE, ALERTS & CONTROLS
| Front Panel LCD Display | LCD DISPLAY: offers a variety of graphical, text and numeric information to indicate a wide range of UPS operation and fault / warning conditions, including current operating mode, alarm status, load level, battery charge, input / output voltage & frequency, estimated runtime and more (see user manual for a detailed listing) | 
| Switches | ON / ENTER BUTTON: turns the UPS on and confirms a selection from the settings menu; OFF / ESC BUTTON: turns off the UPS and returns to the previous item in the settings menu; TEST / UP BUTTON: initiates UPS self-test operation and advances to the next item in the settings menu; MUTE / DOWN BUTTON: silences the audible alarm and advances to the previous item in the settings menu; Press TEST/UP & MUTE/DOWN buttons simultaneously for 1 second to enter or exit the settings menu (See user manual for detailed information) | 
| Audible Alarm | Alarms warn users of a variety of operational conditions: BYPASS MODE (beeps every 2 seconds), BATTERY MODE (beeps every 4 seconds), FAULT MODE (beeps continuously), OVERLOAD (beeps twice per second), OTHER WARNINGS (beeps once per second), FAULT (beeps continuously); All alarms can be silenced, except OVERLOAD & OTHER WARNINGS conditions | 
| LED Indicators | 4 LEDs report BYPASS / LINE / BATTERY / FAULT modes | 
PHYSICAL
| Primary Form Factor | Tower | 
| Cooling Method | Fans | 
| Installation Form Factors Supported with Included Accessories | Tower | 
| Primary UPS Depth (mm) | 813 | 
| Primary UPS Height (mm) | 998 | 
| Primary UPS Width (mm) | 300 | 
| Shipping Dimensions (hwd / in.) | 48.82 x 16.93 x 36.22 | 
| Shipping Weight (lbs.) | 562.18 | 
| UPS Housing Material | Steel | 
| UPS Power Module Dimensions (Height x Width x Depth, mm) | 1000 x 300 x 813 | 
| UPS Power Module Dimensions (hwd, in.) | 39.3 x 11.81 x 32 | 
| UPS Power Module Weight (kg) | 233.60 | 
| UPS Power Module Weight (lbs.) | 515 | 
ENVIRONMENTAL
| Operating Temperature Range | 0 to +40C (32-104F) | 
| Storage Temperature Range | 0 to +35C (32 to 95F) with battery; -15 to 60C (5 to +140F) without battery | 
| Relative Humidity | 5 to 95%, non-condensing | 
| AC Mode BTU / Hr. (Full Load) | 9120 | 
| Operating Elevation (ft.) | < 3000ft (Capacity de-rates by 1% for every 330ft over 3000) | 
| Audible Noise | <65dBA front side 1M | 
| Operating Elevation (m) | < 1000m (Capacity de-rates by 1% for every 100m over 1000) | 
COMMUNICATIONS
| Network Management Cards | WEBCARDLX ; MODBUSCARDSV ; RELAYCARDSV | 
| Network Monitoring Port Description | Card accessory slot also supports network interface and relay card options | 
| Communications Cable | DB9 cabling included | 
| Communications Interface | DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface | 
LINE / BATTERY TRANSFER
| Transfer Time | Zero transfer time in ONLINE MODE (0ms); ECONOMY MODE: 7ms from AC to Battery mode / 0.6ms from Battery to AC mode | 
| Low Voltage Transfer to Battery Power (Setpoint) | 110V (50% load) / 305V (100% load) | 
| High Voltage Transfer to Battery Power (Setpoint) | 520V (50% load) / 478V (100% load) | 
FEATURES & SPECIFICATIONS
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported | 
| High Availability UPS Features | Automatic inverter bypass; Manual bypass switch; Auto Probe Monitoring (requires WEBCARDLX); Zero transfer time; On-Line/Double-Conversion | 
| Green Energy-Saving Features | High efficiency economy mode operation | 
| Grounding Lug | Yes | 
| IP68 Rated | No | 
STANDARDS & COMPLIANCE
| Product Certifications | IEC/EN 62040 | 
| Product Compliance | RoHS; CE (Europe) | 
WARRANTY & SUPPORT
| Product Warranty Period (U.S. & Canada) | 1-year limited warranty | 
| 3-Phase Warranty Statement | Tripp Lite 3-Phase UPS Factory Warranty | 
Additional information
| Weight | 255 kg | 
|---|---|
| Dimensions | 124 × 43 × 91.99 cm | 
| Brand | 